This is description of this part:
Short rack for the longitudinal movement, that is a repair part for the Carl Zeiss 45 35 10 microscope stage used in Zeiss Axiolab microscopes and similar models.
This is the rack that works together with the outer (larger) pinion of the stage manipulator (https://www.microscopeparts.eu/part/99973) and is responsible for moving the stage surface in the front-back axis.
Basic data of this rack:
Length of the rack: 55 mm
Number of teeth: 35
Material: plastic
How it is fixed: with 2 hex socket screws, which are included
Removed from: the mechanical XY stage Zeiss 45 35 10
Which microscope this stage worked with: the Zeiss Axiolab re 45 09 05 microscope
Important: there are two racks of different length in the Zeiss 453510 microscope stage. The one I am offering here is the shorter one, responsible for the longitudinal movement, that is for moving the stage surface back and forth. This rack is not responsible for moving the specimen holder sideways.
The stage this rack comes from was mounted in a Zeiss Axiolab re microscope, P/N 45 09 05 (also written as 450905). However, the same stage model is also mounted on the following variants:
- Zeiss Axiolab drb KT, which carries the same number 45 09 05 (450905)
- Zeiss Axiolab E re, 45 09 07 (450907)
- Zeiss Axiolab A, 45 09 09 (450909)
- Zeiss Axiolab Pol, 45 09 10 (450910)
This item is not a spare part for repairing a microscope. It is a component of the microscope stage - and the stage can be used with any compatible Zeiss microscope, and even with others, onto whose stage carrier such a stage can be fitted or screwed on.
Detailed photos of this rack are available in the gallery. Every photo shows a scale with a millimetre division. The last photo shows the whole Zeiss 453510 microscope stage, with an arrow pointing at the component in question and at where it sits in the stage, so that this part can be identified without any doubt.
What is this part needed for?
- as a repair part, when you want to replace the whole damaged component
- if you have a microscope stage in which this component still works, but is in very poor condition
- if this rack went missing during cleaning or repair of the stage, or if, for example, its plastic teeth have broken off
- What category does this part belong to?
- Service and spare parts [ link ] [More Service and spare parts]
- Who manufactures this part?
-
- Zeiss - Carl Zeiss West Germany [ link ] [More Zeiss]
- Carl Zeiss West
- Carl Zeiss West Germany
- Opton
- What microscope does this part come from?
- Mikroskop Zeiss Axiolab [ link ] [More from Axiolab]
- What microscopes or components is this part compatible with?
-
- - Zeiss 45 35 10 XY microscope stage
- Zeiss Axiolab
- Zeiss Axiolab microscope repair parts
- Zeiss Axiolab Kreuztisch bewegt sich nicht mehr
- Zeiss microscope stage does not move anymore
- Zahnstange Zaehne ausgebrochen Mikroskoptisch
- broken plastic rack teeth microscope stage
- Zeiss 453510 Zahnstange Ersatzteil Kunststoff
- Zeiss Axiolab Tisch Vorwaertsbewegung ohne Funktion
- stage Y axis slipping jumping Zeiss repair
- Zahnstange beim Zerlegen verloren Mikroskoptisch
- rack lost during microscope stage repair
- Zeiss Axiolab Mikroskoptisch zerlegen und neufetten
- microscope stage regrease rack and pinion
- kurze Zahnstange Laengsbewegung Zeiss Kreuztisch
- short rack longitudinal movement Zeiss stage
- Zeiss Axiolab re 450905 Tisch Zahnstange
- Zeiss Axiolab E 450907 Kreuztisch Zahnstange
- Zeiss Axiolab Pol 450910 Tisch Ersatzteil
- Zahnstange und Ritzel Mikroskoptisch Zeiss
- Zeiss Axiolab Mikroskoptisch aufarbeiten
- restoring a Zeiss microscope mechanical stage
- ozubená tyč stolku mikroskopu Zeiss Axiolab
- cremallera de la platina microscopio Zeiss Axiolab
- repuesto cremallera platina microscopio Zeiss
- cremagliera del tavolino microscopio Zeiss Axiolab
- ricambio cremagliera tavolino microscopio Zeiss
- zębatka stolika mikroskopowego Zeiss wyłamane ząbki
- Zeiss buy spare parts