Home page of the microscope service parts, repair and spare parts online catalog - Sermik-Oplatek Mikroskopservice Dresden f.n.n.Z

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.

Advanced search






The table below is the search result: "Vickers + Intermediate tube"

of 2 [Newest first]

Main table with a list of microscope parts

Photos PartIndex Short name Part name Description Number of pieces Price Category Manufacturer It comes from Compatible with Why do you need this? Added ↑

447 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99010
Vickers Patholux microscope magnification changer

The name of this microscope part.

Vickers Patholux microscope magnification changer

Description of this part for the microscope.

Optovar-type magnification changer for the Vickers Patholux microscope.

This magnification changer offers the following magnification steps:
- ...

B (no additional magnification)
- 1.3x
- 2x
- 3x

This is an optional component - an accessory for the Patholux microscope. The magnification changer is mounted between the body and the microscope head.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Vickers Patholux microscope repair parts
  • Vickers Patholux microscope magnification changer | Vickers Patholux Mikroskop Optovar Vergrößerungswechsel | zmieniacz powiększeń do mikroskopu Vickers Patholux | Vickers Patholux Mikroskop Zwischentubus | Vickers Patholux microscope intermediate tube
  • Vickers buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

129 €

Name of the category to which this microscope part is classified.

Intermediate tube

Abbreviated and full name of the manufacturer of this microscope part.

Vickers

Vickers Instruments Ltd.

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Patholux

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Vickers)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as an add-on that expands the microscope's capabilities
2026-02-06 00:00:00

453 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99011
Vickers Patholux microscope intermediate photo tube | trinocular head adapter

The name of this microscope part.

Vickers Patholux microscope intermediate photo tube | trinocular head adapter

Description of this part for the microscope.

Photo tube | trinocular head adapter for the Vickers Patholux microscope.

This is an angled photo tube onto which a binocular microscope head is mounted. ...

After attaching a binocular head, the complete assembly forms a full trinocular head.

Basic features:
- dovetail connection for mounting a binocular microscope head
- upper dovetail connection for mounting a photographic adapter
- a tube adapter for 23.2 mm projection eyepieces is currently mounted on this connection
- operating modes: manually switchable light beam split 0 / 100 or 100 / 0

This microscope element is also referred to as:
- photographic adapter
- trino dome
- photo intermediate tube

It is POSSIBLE that this photo tube also fits other microscopes manufactured by Vickers. Detailed mounting interface dimensions will be added soon, which will allow verification of compatibility with other models.

As of today, this adapter is known to fit the following microscopes:
- Vickers Patholux
- Vickers Patholette

Note - please pay attention to paint damage and scratches. These occurred during transport and do not affect optical quality or the operation of this microscope element, but they do reduce its external condition. I did not hide or repaint them so that you have full insight into the actual condition of the item.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Vickers Patholux microscope repair parts
  • Vickers Patholux microscope photo head | Vickers Patholux Mikroskop Foto-Winkeltubus | głowica fotograficzna do mikroskopu Vickers Patholux | Vickers Patholux Mikroskop Trinokular Fotutubus | Vickers Patholux microscope intermediate photo tube
  • Vickers buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

99 €

Name of the category to which this microscope part is classified.

Intermediate tube

Abbreviated and full name of the manufacturer of this microscope part.

Vickers

Vickers Instruments Ltd.

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Patholux

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Vickers)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if you own a compatible Vickers microscope in which this element is missing
  • if you own a compatible Vickers microscope with a binocular head and want to expand it with a photographic adapter to a trinocular version
  • if you already have a microscope with such a trinocular head but the optics are in poor condition or damaged - then you can use this item as a service replacement element
  • if you want to try mounting this tube on another microscope, possibly even from a different manufacturer
2026-02-10 00:00:00