Home page of the microscope service parts, repair and spare parts online catalog - Sermik-Oplatek Mikroskopservice Dresden f.n.n.Z

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.

Advanced search






The table below is the search result: "Prisms + Leitz"

of 3 [Newest first]

Main table with a list of microscope parts

Photos PartIndex Short name Part name Description Number of pieces Price Category Manufacturer It comes from Compatible with Why do you need this? Added ↑

1277 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

91072
Leitz Wetzlar microscope central beamsplitter prism for binocular head 512582

The name of this microscope part.

Leitz Wetzlar microscope central beamsplitter prism for binocular head 512582

Description of this part for the microscope.

Central prism for the Leitz Wetzlar microscope head. This is the central beamsplitter prism.

This prism was removed from a Leitz Wetzlar binocular head P/N 512582 ...

- but exactly the same prisms are also used in other models of binocular and trinocular heads.

It is neither the right nor the left eyepiece prism. It is the central prism that splits the beam towards the right and the left eye.

The last photo in the gallery shows a disassembled Leitz Wetzlar 512582 binocular head, with an arrow pointing to the prism in question and to its position inside the head. This makes the part easy to identify.

Replacing this prism in a Leitz Wetzlar microscope head can be the remedy for the following problems:
- if the prism in your head is mechanically damaged: it may be cracked or chipped
- if the prism to be replaced has a damaged anti-reflective coating: this may be caused by fungus, or the coating may be scratched by improper cleaning
- if discolouration or separation (delamination) is visible inside the prism. This is a cemented prism, and over the years the cement can discolour or come apart in places, which is unfortunately visible in the field of view while working with the microscope
- if the reflective layer inside the prism (usually silver) oxidises and loses its properties in places or completely

Before you decide to use this prism in a Leitz Wetzlar head other than model 512582, first compare the exact dimensions (a millimetre scale is visible in the photos) and, if in doubt, ask on internet groups and forums.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux microscope repair parts
  • Leitz Wetzlar 512582 beamsplitter prism replacement
  • Leitz Wetzlar Laborlux binocular head prism DIY repair
  • Leitz Wetzlar HM-Lux Mikroskop Prisma im Binokulartubus reparieren
  • Leitz Dialux Strahlenteilerprisma Ersatz für den Binokularkopf
  • cracked beamsplitter prism Leitz microscope binocular head
  • delaminated prism Leitz Dialux microscope head
  • Strahlenteilerprisma gesprungen Leitz Wetzlar Mikroskop
  • Prisma Pilzbefall Leitz Wetzlar Laborlux Mikroskopkopf
  • pryzmat światłodzielący do głowicy mikroskopu Leitz Wetzlar
  • dělicí hranol do binokulární hlavy mikroskopu Leitz
  • prisma divisor de haz cabezal binocular microscopio Leitz
  • prisma central microscopio Leitz Wetzlar repuesto
  • prisma divisore di fascio testa binoculare microscopio Leitz
  • prisma centrale microscopio Leitz Wetzlar ricambio
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

15 €

Name of the category to which this microscope part is classified.

Prisms

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

  • Dialux
  • Leitz Wetzlar 512582 binocular
  • Leitz Wetzlar Laborlux
  • Leitz Wetzlar HM-Lux

A list of potential uses for this part and when it might be needed.

  • as a service part, to be fitted in a head with a damaged central prism, e.g. scratched, chipped, delaminated, with an oxidised reflective layer or damaged by fungus
2026-10-09 12:04:40

1278 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

91073
Leitz Wetzlar microscope left eyepiece prism for binocular head 512582

The name of this microscope part.

Leitz Wetzlar microscope left eyepiece prism for binocular head 512582

Description of this part for the microscope.

Left eyepiece prism for the Leitz Wetzlar microscope head. This is the prism that passes the light beam from the central beamsplitter prism on to the left eyepiece. ...



This prism was removed from a Leitz Wetzlar binocular head P/N 512582 - but exactly the same one is also used in other models of binocular and trinocular heads.

The last photo in the gallery shows a disassembled Leitz Wetzlar 512582 binocular head, with an arrow pointing to the prism in question and to its position inside the head. This makes the part easy to identify.

Replacing this prism in a Leitz Wetzlar microscope head can be the remedy for the following problems:
- if the prism in your head is mechanically damaged: it may be cracked or chipped
- if the prism to be replaced has a damaged anti-reflective coating: this may be caused by fungus, or the coating may be scratched by improper cleaning
- if discolouration or separation (delamination) is visible inside the prism. Over the years the cement can discolour or come apart in places, which is unfortunately visible in the field of view while working with the microscope
- if the reflective layer oxidises and loses its properties in places or completely

Before you decide to use this prism in a Leitz Wetzlar head other than model 512582, first compare the exact dimensions (a millimetre scale is visible in the photos) and, if in doubt, ask on internet groups and forums.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux microscope repair parts
  • Leitz Wetzlar 512582 left eyepiece prism replacement
  • Leitz Wetzlar Laborlux binocular head prism DIY repair
  • Leitz Wetzlar HM-Lux Mikroskop Prisma im Binokulartubus reparieren
  • Leitz Dialux Okularprisma Ersatz für den Binokularkopf
  • cracked left eyepiece prism Leitz microscope binocular head
  • delaminated prism Leitz Dialux microscope head
  • Okularprisma gesprungen Leitz Wetzlar Mikroskop
  • Prisma Pilzbefall Leitz Wetzlar Laborlux Mikroskopkopf
  • lewy pryzmat okularowy do głowicy mikroskopu Leitz Wetzlar
  • hranol do binokulární hlavy mikroskopu Leitz
  • prisma cabezal binocular microscopio Leitz
  • prisma del ocular izquierdo para microscopio Leitz Wetzlar (repuesto)
  • prisma testa binoculare microscopio Leitz
  • ricambio per prisma dell'oculare sinistro di microscopio Leitz Wetzlar
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

15 €

Name of the category to which this microscope part is classified.

Prisms

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

  • Dialux
  • Leitz Wetzlar 512582 binocular
  • Leitz Wetzlar Laborlux
  • Leitz Wetzlar HM-Lux

A list of potential uses for this part and when it might be needed.

  • as a service part, to be fitted in a head with a damaged left prism, e.g. scratched, chipped, delaminated, with an oxidised reflective layer or damaged by fungus
2026-10-09 12:48:12

1279 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

91074
Leitz Wetzlar microscope right eyepiece prism for binocular head 512582

The name of this microscope part.

Leitz Wetzlar microscope right eyepiece prism for binocular head 512582

Description of this part for the microscope.

Right eyepiece prism for the Leitz Wetzlar microscope head. This is the prism that passes the light beam from the central beamsplitter prism on to the left eyepiece. ...



This prism was removed from a Leitz Wetzlar binocular head P/N 512582 - but exactly the same one is also used in other models of binocular and trinocular heads.

Right means right as seen by the observer looking into the eyepieces. It is neither the central prism that splits the beam towards both eyes, nor the left eyepiece prism.

The last photo in the gallery shows a disassembled Leitz Wetzlar 512582 binocular head, with an arrow pointing to the prism in question and to its position inside the head. This makes the part easy to identify.

Replacing this prism in a Leitz Wetzlar microscope head can be the remedy for the following problems:
- if the prism in your head is mechanically damaged: it may be cracked or chipped
- if the prism to be replaced has a damaged anti-reflective coating: this may be caused by fungus, or the coating may be scratched by improper cleaning
- if discolouration or separation (delamination) is visible inside the prism. Over the years the cement can discolour or come apart in places, which is unfortunately visible in the field of view while working with the microscope
- if the reflective layer oxidises and loses its properties in places or completely

Before you decide to use this prism in a Leitz Wetzlar head other than model 512582, first compare the exact dimensions (a millimetre scale is visible in the photos) and, if in doubt, ask on internet groups and forums.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux microscope repair parts
  • Leitz Wetzlar 512582 right eyepiece prism replacement
  • Leitz Wetzlar Laborlux binocular head prism DIY repair
  • Leitz Wetzlar HM-Lux Mikroskop Prisma im Binokulartubus reparieren
  • Leitz Dialux Okularprisma Ersatz für den Binokularkopf
  • cracked right eyepiece prism Leitz microscope binocular head
  • delaminated prism Leitz Dialux microscope head
  • Okularprisma gesprungen Leitz Wetzlar Mikroskop
  • Prisma Pilzbefall Leitz Wetzlar Laborlux Mikroskopkopf
  • prawy pryzmat okularowy do głowicy mikroskopu Leitz Wetzlar
  • hranol do binokulární hlavy mikroskopu Leitz
  • prisma cabezal binocular microscopio Leitz
  • prisma del ocular derecho para microscopio Leitz Wetzlar (repuesto)
  • prisma testa binoculare microscopio Leitz
  • ricambio per prisma dell'oculare destro di microscopio Leitz Wetzlar
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

14 €

Name of the category to which this microscope part is classified.

Prisms

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

  • Dialux
  • Leitz Wetzlar 512582 binocular
  • Leitz Wetzlar Laborlux
  • Leitz Wetzlar HM-Lux

A list of potential uses for this part and when it might be needed.

  • as a service part, to be fitted in a head with a damaged right prism, e.g. scratched, chipped, delaminated, with an oxidised reflective layer or damaged by fungus
2026-10-09 12:59:27