Home page of the microscope service parts, repair and spare parts online catalog - Sermik-Oplatek Mikroskopservice Dresden f.n.n.Z

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.

Advanced search






The table below is the search result: "Carl Zeiss Jena Jenamed + Condensers"

of 3 [Newest first]

Main table with a list of microscope parts

Photos PartIndex Short name Part name Description Number of pieces Price Category Manufacturer It comes from Compatible with Why do you need this? Added ↑

900 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99454
Carl Zeiss Jena Jenamed microscope condenser

The name of this microscope part.

Carl Zeiss Jena Jenamed microscope condenser

Description of this part for the microscope.

Microscope condenser for Carl Zeiss Jena Jenamed microscopes.

This particular example shown and offered here was removed from a Carl Zeiss Jena Jenamed Cytology ...

microscope. It will most likely also fit other models from the Jenamed series (e.g. Jenamed Variant, Jenamed Fluorescence, Jenamed-2, Jenamed Hematology). Please note however that the Carl Zeiss Jena Jenamed Histology microscope is factory-equipped with a different type of condenser - the "flip-out" type.

To make sure whether this condenser will fit a specific Carl Zeiss Jena microscope from the Jenamed series, it is best to carefully check all dimensions based on the gallery photos or ask a question on a professional forum, e.g. https://www.mikroskopie-forum.de/

Mechanically, this condenser is mounted from the underside of the microscope stage - first it is screwed into the threaded opening in the stage and then secured with three screws. The upper lens can be unscrewed to obtain a condenser with a lower numerical aperture N.A. This condenser does not have an iris diaphragm installed because in Jenamed microscopes it is a separate element.

Replacing the condenser in a Carl Zeiss Jena Jenamed microscope may be necessary:
- when the upper lens becomes damaged, for example when it turns matte due to exposure to various chemical reagents
- when the upper lens becomes damaged due to rubbing. Surprisingly, this unusual type of damage is very common after several decades of microscope use.

In the last photo I indicate with an arrow exactly which element it is and where it is located in the microscope.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Carl Zeiss Jena Jenamed microscope repair parts
  • Carl Zeiss Jena Jenamed microscope condenser
  • kondensor do mikroskopu Carl Zeiss Jena Jenamed
  • Carl Zeiss Jena Jenamed Mikroskop-Kondensor
  • Carl Zeiss Jena buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

69 €

Name of the category to which this microscope part is classified.

Condensers

Abbreviated and full name of the manufacturer of this microscope part.

Carl Zeiss Jena

VEB Carl Zeiss Jena DDR (former East Germany)

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Jenamed

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Carl Zeiss Jena)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as a repair part in the form of replacing the complete part if it or one of its elements is damaged or of very poor quality
  • several examples of applications are given in the description
2026-05-28 22:33:24

910 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99468
Carl Zeiss Jena Jenamed Histology microscope condenser

The name of this microscope part.

Carl Zeiss Jena Jenamed Histology microscope condenser

Description of this part for the microscope.

Microscope condenser for Carl Zeiss Jena Jenamed Histology microscopes.

It DOES NOT FIT other Carl Zeiss Jena microscope models from the Jenamed series and ...

therefore cannot be used in:
- Jenamed Cytology
- Jenamed Variant
- Jenamed Hematology
- Jenamed Fluorescence
- Jenamed-2

Mechanically, this condenser is a "flip-out" design and is mounted in a metal frame together with a lever used to rotate it in order to obtain one of two operating modes: low or high numerical aperture N.A. This lever extends outside the microscope housing so that the user can operate it.

The complete module is mounted underneath the microscope stage by attaching the entire condenser assembly from below with four screws. This condenser does not contain an iris diaphragm because, in Jenamed microscopes, it is a separate component mounted beneath the condenser.

In the Carl Zeiss Jena Jenamed Histology microscope, this condenser is not used together with the wide-field lens that is installed beneath the condenser in other Jenamed models (part Si10 CZ 2711-1). In the Jenamed Histology model, a polarizer is installed in this position instead.

Replacement of the condenser in a Carl Zeiss Jena Jenamed Histology microscope may be necessary:
- when the upper lens becomes damaged, for example by becoming cloudy due to exposure to various chemical reagents
- when the upper lens is damaged by friction. Surprisingly, this unusual type of damage is very common after several decades of microscope use
- when the mechanical lens switching mechanism ("flip-out") becomes damaged

Metal cast or injection-moulded microscope parts manufactured by Carl Zeiss Jena carry their own part numbers. This condenser module bears number 2713 (full marking: Si10 CZ 2713).

In the last photograph, I indicate with an arrow exactly which component is being offered and where it is located within the microscope.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Carl Zeiss Jena Jenamed microscope repair parts
  • Carl Zeiss Jena Jenamed microscope condenser
  • kondensor do mikroskopu Carl Zeiss Jena Jenamed
  • Carl Zeiss Jena Jenamed Mikroskop-Kondensor
  • Carl Zeiss Jena buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

100 €

Name of the category to which this microscope part is classified.

Condensers

Abbreviated and full name of the manufacturer of this microscope part.

Carl Zeiss Jena

VEB Carl Zeiss Jena DDR (former East Germany)

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Jenamed

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Carl Zeiss Jena)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as a repair part in the form of replacing the complete part if it or one of its elements is damaged or of very poor quality
  • several examples of applications are given in the description
2026-05-30 22:51:40

911 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99471
Carl Zeiss Jena Jenamed-2 microscope condenser

The name of this microscope part.

Carl Zeiss Jena Jenamed-2 microscope condenser

Description of this part for the microscope.

Microscope condenser for Carl Zeiss Jena Jenamed-2 microscopes.

It can be used in the following Carl Zeiss Jena microscopes:
- Jenamed-2
- Jenamed- ...

2 Fluorescence

It DOES NOT FIT Carl Zeiss Jena microscopes from the Jenamed series and therefore cannot be used in:
- Jenamed Cytology
- Jenamed Variant
- Jenamed Hematology
- Jenamed Histology

Mechanically, this condenser is mounted on the microscope stage support plate (stage support). The microscope stage is installed onto this support plate together with the condenser. The upper condenser lens can be unscrewed - after removing it, the condenser operates with a lower numerical aperture N.A.

This condenser does not contain an iris diaphragm because, in Jenamed microscopes, it is a separate component mounted beneath the condenser.

Replacement of the condenser in a Carl Zeiss Jena Jenamed-2 microscope may be necessary:
- when the upper lens becomes damaged, for example by becoming cloudy due to exposure to various chemical reagents (common in fluorescence applications)
- when the upper lens is damaged by friction. Surprisingly, this unusual type of damage is very common after several decades of microscope use

Metal cast or injection-moulded microscope parts manufactured by Carl Zeiss Jena carry their own part numbers. The microscope stage support plate on which the condenser is mounted bears number 3030 (full marking: Si10 CZ 3030).

In the last photograph, I indicate with an arrow exactly which component is being offered and where it is located within the microscope.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Carl Zeiss Jena Jenamed microscope repair parts
  • Carl Zeiss Jena Jenamed-2 microscope condenser
  • kondensor do mikroskopu Carl Zeiss Jena Jenamed-2
  • Carl Zeiss Jena Jenamed-2 Mikroskop-Kondensor
  • Carl Zeiss Jena buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

89 €

Name of the category to which this microscope part is classified.

Condensers

Abbreviated and full name of the manufacturer of this microscope part.

Carl Zeiss Jena

VEB Carl Zeiss Jena DDR (former East Germany)

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Jenamed

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Carl Zeiss Jena)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

  • Carl Zeiss Jena Jenamed-2
  • Carl Zeiss Jena Jenamed-2 Fluorescence
  • Jenamed

A list of potential uses for this part and when it might be needed.

  • as a repair part in the form of replacing the complete part if it or one of its elements is damaged or of very poor quality
  • several examples of applications are given in the description
2026-05-30 23:17:56