Home page of the microscope service parts, repair and spare parts online catalog - Sermik-Oplatek Mikroskopservice Dresden f.n.n.Z

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.

Advanced search






The table below is the search result: "Leica DMLM + Intermediate tube"

of 2 [Newest first]

Main table with a list of microscope parts

Photos PartIndex Short name Part name Description Number of pieces Price Category Manufacturer It comes from Compatible with Why do you need this? Added ↑

893 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99448
Leica DMLB / DMLS angle tube for P/N 501501 microscope binocular head

The name of this microscope part.

Leica DMLB / DMLS angle tube for P/N 501501 microscope binocular head

Description of this part for the microscope.

Angle tube, i.e. a part of the Leica 501501 microscope binocular head, most commonly used in Leica DM L-serie microscopes:
- Leica DMLS
- Leica DMLB
- ...

Leica DMLM
This element provides an ergonomic, inclined positioning of the head relative to the user's eyes.

The element with manufacturer part number 501501 consists of two main parts:
- angle tube
- binocular head (also referred to as binocular).
Here, only the angle tube is shown and offered, without the binocular head.

Basic parameters:
- mounting to microscope stand: 44,5 mm dovetail
- mounting of the head to the angle tube: three screws

This angle tube can solve the following problems in Leica DMLB / DMLS microscopes:
- if the plastic housing of the angle tube from head P/N 501501 becomes damaged (for example cracked after a fall)
- if the internal prism inside the angle tube from head P/N 501501 becomes damaged: chipped, damaged by fungus, discolored or delaminated
- if the lower lens (from the microscope body side) or upper lens (under the binocular head) inside the angle tube from head P/N 501501 becomes damaged, scratched or loses its anti-reflection coating

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leica DMLS microscope repair parts
  • Leica DMLB / DMLS Mikroskop Zwischentubus
  • Leica DMLB microscope binocular head angle tube
  • Leica DMLS Mikroskop Winkeltubus
  • Leica DMLB Mikroskop 501501 Binokular
  • Leica buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

59 €

Name of the category to which this microscope part is classified.

Intermediate tube

Abbreviated and full name of the manufacturer of this microscope part.

Leica

Leica Microsystems GmbH

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

DMLS

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leica)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as a service part if the prism in the existing tube is damaged
  • if you have a binocular head without an angle tube and want to mount it on a Leica DM L-serie microscope
  • if you need an angle tube for your own DIY project
2026-05-26 20:52:09

894 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99446
Leica DMLB / DMLS angle tube for P/N 501055 microscope binocular head

The name of this microscope part.

Leica DMLB / DMLS angle tube for P/N 501055 microscope binocular head

Description of this part for the microscope.

Angle tube, i.e. a part of the Leica 501055 microscope binocular head, most commonly used in Leica DM L-serie microscopes:
- Leica DMLS
- Leica DMLB
- ...

Leica DMLM
This element provides an ergonomic, inclined positioning of the head relative to the user's eyes.

The element with manufacturer part number 501055 consists of two main parts:
- angle tube
- binocular head (also referred to as binocular).
Here, only the angle tube is shown and offered, without the binocular head.

Basic parameters:
- mounting to microscope stand: 44,5 mm dovetail
- mounting of the head to the angle tube: three screws

This angle tube can solve the following problems in Leica DMLB / DMLS microscopes:
- if the plastic housing of the angle tube from head P/N 501055 becomes damaged (for example cracked after a fall)
- if the internal prism inside the angle tube from head P/N 501055 becomes damaged: chipped, damaged by fungus, discolored or delaminated
- if the lower lens (from the microscope body side) or upper lens (under the binocular head) inside the angle tube from head P/N 501055 becomes damaged, scratched or loses its anti-reflection coating

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leica DMLS microscope repair parts
  • Leica DMLB / DMLS Mikroskop Zwischentubus
  • Leica DMLB microscope binocular head angle tube
  • Leica DMLS Mikroskop Winkeltubus
  • Leica DMLB Mikroskop 501055 Binokular
  • Leica buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

59 €

Name of the category to which this microscope part is classified.

Intermediate tube

Abbreviated and full name of the manufacturer of this microscope part.

Leica

Leica Microsystems GmbH

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

DMLS

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leica)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as a service part if the prism in the existing tube is damaged
  • if you have a binocular head without an angle tube and want to mount it on a Leica DM L-serie microscope
  • if you need an angle tube for your own DIY project
2026-05-26 21:02:27