Home page of the microscope service parts, repair and spare parts online catalog - Sermik-Oplatek Mikroskopservice Dresden f.n.n.Z

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.

Advanced search






The table below is the search result: "Leitz Laborlux S + Dialux"

of 6 [Newest first]

Main table with a list of microscope parts

Photos PartIndex Short name Part name Description Number of pieces Price Category Manufacturer It comes from Compatible with Why do you need this? Added ↑

992 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99547
Leitz Dialux Wetzlar specimen holder for mechanical XY microscope stage

The name of this microscope part.

Leitz Dialux Wetzlar specimen holder for mechanical XY microscope stage

Description of this part for the microscope.

Spring-loaded specimen holder for the mechanical XY microscope stage used on various Leitz Wetzlar microscope models.

This particular specimen holder was removed ...

from a Leitz Dialux microscope. In the last photo in the gallery you can see the microscope stage from which it was removed. However, the manufacturer fitted the same type of mechanical XY microscope stage to many other Leitz microscope models, so this specimen holder is also compatible with models other than the Leitz Dialux.

When determining compatibility and whether this specimen holder can be mounted on a particular mechanical XY microscope stage, the following dimensions are critical:
- distance between the two side locating pins: 81 mm measured from the outer edge of one pin to the outer edge of the other pin
- locating pin diameter: 3 mm each
- therefore, the centre-to-centre distance between the locating pins is 78 mm
- diameter of the central mounting screw: 4 mm
- position of the mounting screw: centred between the two locating pins

If the spacing of the locating pins matches, this specimen holder can also be mounted on microscope stages made by other manufacturers.

Leitz Wetzlar produced specimen holders with fixed stage clips as well as versions with a spring-loaded stage clip. Here I am showing and offering the spring-loaded version.

On the used market and in technical documentation, this microscope part is described using a variety of names. Common terms include:
- specimen holder
- microscope stage specimen holder
- mechanical stage specimen holder
- slide holder
- microscope slide holder
- microscope slide clamp
- spring-loaded specimen holder
- spring-loaded slide holder
- spring-loaded stage clip
- specimen clamp
- specimen carrier
- mechanical stage carrier
- XY stage specimen holder
- specimen holder for mechanical XY microscope stage
- stage holder
- stage clip assembly

The photographs in the gallery show the exact dimensions of the microscope part offered here. In addition, the last photograph includes an arrow indicating exactly which microscope part is being described and where it is mounted on the mechanical XY microscope stage, making identification straightforward. The accompanying video demonstrates the operation of the spring-loaded stage clip.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux microscope repair parts
  • Leitz Wetzlar microscope stage specimen holder
  • Leitz Wetzlar mikroskoptisch Objektführer
  • Leitz Wetzlar XY Kreuztisch Kreuzmechanismus
  • Leitz Wetzlar Mikroskop Kreuztisch Präparathalter
  • Leitz Dialux Präparathalter Kreuztisch
  • Leitz Dialux stage specimen holder
  • držák preparátu Leitz Dialux
  • pinza de preparados Leitz Dialux
  • repuesto platina microscopio Leitz SM
  • pinza portavetrini Leitz Dialux
  • ricambio tavolino microscopio Leitz SM
  • uchwyt preparatu Leitz Dialux
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

39 €

Name of the category to which this microscope part is classified.

XY-stages (specimen holders)

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if you have a stage that is missing the specimen holder
  • if you have a "simple" specimen holder and want to replace it with one with a spring-loaded clamp
  • if you want to install this holder on a stage in a microscope from another manufacturer
2026-06-30 01:20:47

993 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99546
Leitz Dialux Wetzlar mechanical manipulator for XY microscope stage

The name of this microscope part.

Leitz Dialux Wetzlar mechanical manipulator for XY microscope stage

Description of this part for the microscope.

Complete manipulator of the mechanical XY stage for Leitz Wetzlar microscopes.

This is a complete control assembly for the mechanical microscope stage, ...

allowing precise movement of the specimen in both the X and Y axes of the stage plane. The manipulator consists of two coaxial knobs, two independent drive shafts and the fixing elements that attach it to the stage mechanism.

This particular manipulator was removed from a Leitz Dialux microscope. The last photograph in the gallery shows the entire microscope stage from which it was dismounted. The manufacturer also used the same or very similar stages in many other Leitz Wetzlar microscope models, which is why the manipulator may also be compatible with other models from this company.

On the second-hand market and in service documentation one encounters many names referring to this assembly. The most commonly used terms include, among others:
- stage manipulator
- XY stage manipulator
- mechanical stage drive
- stage control knobs
- specimen mover
- coaxial stage drive
- stage drive assembly
- mechanical stage control
- manual XY stage drive
- stage actuator mechanism

Such manipulators very often suffer mechanical damage during transport of the microscope. Because they protrude beyond the outline of the stand, it is precisely they that absorb the impact energy first - in the event of a fall or improper packaging of the instrument.

In many cases it is not the entire manipulator that is damaged, but only one of its components. Most often these are the knobs, the drive shafts, the coaxial sleeves or the fixing elements. For this reason, this database also contains all the most important constituent parts of this (and other) manipulators, offered separately as service elements.

Damage to the manipulator does not make further work with the microscope impossible. The specimen can be moved by hand, or a simple specimen holder without an XY movement mechanism can be fitted. Such a solution works well at low magnifications; however, when working with objectives of magnifications greater than 40x (e.g. 60x, 63x, 80x or 100x), precise manual movement of the specimen becomes very difficult. At total magnifications exceeding about 400x, even a slight movement of the hand shifts the image by a considerable distance within the field of view. The mechanical manipulator enables very smooth, controlled and repeatable movement of the specimen in both axes, which is particularly important during observation with oil immersion and when producing photographic documentation.

The photographs in the gallery show the exact dimensions of the complete manipulator. The last photograph presents the entire microscope stage together with an arrow indicating the mounting location of this element, which makes it possible to identify the offered part unambiguously.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux microscope repair parts
  • Leitz Wetzlar microscope stage micromanipulator
  • Leitz Wetzlar mikroskoptisch Bedienknopf
  • Leitz Wetzlar XY Kreuztisch-Manipulator
  • Leitz Dialux Kreuztisch Trieb
  • Leitz Dialux XY stage manipulator
  • posuv stolku Leitz Dialux
  • manipulador de platina Leitz Dialux
  • repuesto platina microscopio Leitz SM
  • manipolatore tavolino Leitz Dialux
  • ricambio tavolino microscopio Leitz SM
  • manipulator stolika Leitz Dialux
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

29 €

Name of the category to which this microscope part is classified.

Service and spare parts

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if you have an incomplete Leitz microscope stage in which this manipulator is missing (e.g. someone did not finish the repair)
  • if you have a Leitz microscope stage in which the manipulator does not work or is of very poor quality (it turns stiffly or unevenly)
  • if you need a precise coaxial mechanism for your own DIY project, e.g. related to macro photography or rotating an object for 3D films
2026-06-30 02:45:07

1333 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99928
Leitz Wetzlar 512821/20 microscope eyepiece tube with diopter adjustment ring for binocular head

The name of this microscope part.

Leitz Wetzlar 512821/20 microscope eyepiece tube with diopter adjustment ring for binocular head

Description of this part for the microscope.

Eyepiece tube with diopter adjustment ring for the Leitz Wetzlar 512821/20 microscope binocular head and similar heads.

This tube was removed from the Leitz ...

Wetzlar binocular head P/N 512821/20 (also written 512 821) - but exactly the same tube is used in other models of binocular and trinocular heads as well.

The same front panel design is found in, among others, the Leitz 512 923/20 and Leitz 512 815 trinocular heads - this tube with diopter adjustment will most likely fit those too.

Diameter of the eyepieces it takes: 23.2 mm.

In the Leitz bino 512821/20 both the left and the right tube have diopter adjustment. They are mechanically identical parts - there is no difference between the left and the right tube. They can be swapped.

Before you decide to use this tube in a Leitz Wetzlar head other than model 512 821/20, first compare the exact dimensions (the photos show a millimetre scale), and if you have any doubts, ask in internet groups and forums.

This is a service part for a microscope head - not for a specific microscope model. Such a head can be mounted on many Leitz Wetzlar microscope models (and even on microscopes from other makers), so no list of microscopes this tube fits can be given - it fits the head, and the user mounts the head wherever he wants.

In the "compatibility" section I list a few example Leitz Wetzlar microscope models that turn up on the second-hand market complete with the head this tube comes from - but this is definitely not a complete list. They include:
- Leitz Wetzlar Dialux 20 / Dialux 22 EB
- Leitz Wetzlar Laborlux K / Laborlux S
- Leitz Wetzlar Diaplan

On the last photos in the gallery you can see the Leitz Wetzlar 512821/20 binocular head taken apart, with an arrow pointing to which part this is and where it sits in the head. That makes it unambiguous to identify.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux 20 microscope repair parts
  • keywords Leitz 512821/20 Okularstutzen mit Dioptrienring
  • Leitz 512 821 binocular head eyepiece tube replacement
  • Leitz Dialux 20 Binokularkopf Okularstutzen tauschen
  • Leitz Dialux 22 EB eyepiece tube with diopter adjustment
  • Leitz Laborlux S Okulartubus 23.2 mm Ersatz
  • Leitz Laborlux K binocular head eyepiece tube 23.2 mm
  • Leitz Diaplan Okularstutzen 23.2 mm
  • Leitz 512 815 trinocular head eyepiece tube
  • Dioptrienring am Leitz Binokulartubus dreht durch
  • Okularstutzen am Leitz Dialux verbogen
  • Leitz binocular head diopter ring stuck - replacement tube
  • Leitz Ortholux eyepiece tube missing 23.2 mm
  • Leitz SM-LUX Bino Okularstutzen 23.2 mm
  • Leitz Laborlux 12 binocular head eyepiece tube repair DIY
  • Leitz Ortholux Binokularkopf aufarbeiten Okularstutzen
  • okulárový tubus 23.2 mm k binokulární hlavici Leitz
  • tubo portaocular 23.2 mm cabezal binocular Leitz Dialux
  • ajuste de dioptrías cabezal binocular Leitz Laborlux
  • tubo portaoculare 23.2 mm testata binoculare Leitz Dialux
  • regolazione diottrica testata binoculare Leitz Laborlux
  • tubus okularowy 23.2 mm do głowicy Leitz - wymiana
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

2

Price in EURO for 1 piece of this microscope part. Price is negotiable.

15 €

Name of the category to which this microscope part is classified.

Service and spare parts

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux 20

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • very often this tube is dented and an eyepiece cannot be inserted
  • very often the diopter adjustment ring becomes damaged and does not function
  • if you want diopter adjustment on both eyepiece tubes and replace the simple tube with one equipped with an adjustment ring
  • if you need a tube with precise worm adjustment for your own DIY purposes
2026-10-22 22:35:38

1334 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99929
Leitz Wetzlar 512821/20 microscope interpupillary adjustment mechanism for binocular head

The name of this microscope part.

Leitz Wetzlar 512821/20 microscope interpupillary adjustment mechanism for binocular head

Description of this part for the microscope.

Internal interpupillary distance adjustment mechanism for the Leitz Wetzlar 512821/20 microscope binocular head and similar heads.

The set offered here consists ...

of:
- two brass carrier plates, each with a round seat for the eyepiece tube (it is to these plates that the tubes https://www.microscopeparts.eu/part/99928 are screwed)
- a central scissor lever made of plastic, with its fixing screw
- two pressure springs (one for each brass plate)

Turning the central lever moves both brass plates outwards symmetrically. It is exactly this constant work of the plastic central lever against the brass plates that wears the plastic lever out - and then it has to be replaced.

This mechanism was removed from the Leitz Wetzlar binocular head P/N 512821/20 (also written 512 821) - but exactly the same one is used in other models of binocular and trinocular heads as well.

The same front panel design is found in, among others, the Leitz 512 923/20 and Leitz 512 815 trinocular heads - this interpupillary mechanism will most likely fit those too.

From the outside this mechanism is covered by plastic covers - one on the right (https://www.microscopeparts.eu/part/99931) and a different one on the left (https://www.microscopeparts.eu/part/99930). These plastic covers carry a printed scale on which the interpupillary distance is read.

Before you decide to use this mechanism in a Leitz Wetzlar head other than model 512 821/20, first compare the exact dimensions (the photos show a millimetre scale), and if you have any doubts, ask in internet groups and forums.

This is a service part for a microscope head - not for a specific microscope model. Such a head can be mounted on many Leitz Wetzlar microscope models (and even on microscopes from other makers), so no list of microscopes this mechanism fits can be given - it fits the head, and the user mounts the head wherever he wants.

In the "compatibility" section I list a few example Leitz Wetzlar microscope models that turn up on the second-hand market complete with the head this mechanism comes from - but this is definitely not a complete list. They include:
- Leitz Wetzlar Dialux 20 / Dialux 22 EB
- Leitz Wetzlar Laborlux K / Laborlux S
- Leitz Wetzlar Diaplan

On the last photos in the gallery you can see the Leitz Wetzlar 512821/20 binocular head, and with arrows I try to show which part this is and where it sits in the head.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux 20 microscope repair parts
  • keywords Leitz 512821/20 Augenabstand-Verstellung Binokularkopf
  • Leitz 512 821 interpupillary adjustment mechanism replacement
  • Leitz Dialux 20 Augenabstand lässt sich nicht verstellen
  • Leitz Dialux 22 EB binocular head interpupillary mechanism
  • Leitz Laborlux S Scherenhebel Kunststoff gebrochen
  • Leitz Laborlux K binocular head eye distance lever broken
  • Leitz Diaplan Augenabstand-Verstellmechanismus Ersatzteil
  • Leitz 512 815 trinocular head interpupillary mechanism
  • Leitz Bino Augenabstand wackelt - Verstellung ausgeschlagen
  • Leitz binocular head will not hold eye distance setting
  • Leitz Ortholux Binokularkopf Augenabstand Mechanik
  • Leitz SM-LUX Bino Messing-Trägerplatten Okularstutzen
  • Leitz Laborlux 12 binocular head repair DIY interpupillary
  • Leitz Ortholux Binokularkopf aufarbeiten Augenabstand-Mechanik
  • mechanismus nastavení očního rozestupu binokulární hlavice Leitz
  • mecanismo de distancia interpupilar cabezal binocular Leitz Dialux
  • palanca de ajuste interpupilar cabezal binocular Leitz Laborlux
  • meccanismo distanza interpupillare testata binoculare Leitz Dialux
  • leva di regolazione interpupillare testata binoculare Leitz Laborlux
  • mechanizm rozstawu źrenic do głowicy Leitz - wymiana
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

10 €

Name of the category to which this microscope part is classified.

Service and spare parts

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux 20

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as a service part in the form of a complete module, if this part in your microscope head has been damaged
  • as a source for the central scissor lever, which, being a plastic part, often wears out or breaks
2026-10-22 23:24:07

1335 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99931
Leitz Wetzlar 512821/20 microscope right front cover plate for binocular head

The name of this microscope part.

Leitz Wetzlar 512821/20 microscope right front cover plate for binocular head

Description of this part for the microscope.

Right plastic front cover plate for the Leitz Wetzlar 512821/20 microscope binocular head and similar heads.

This is the right one of two covers that close the ...

internal interpupillary distance adjustment mechanism from the front (https://www.microscopeparts.eu/part/99929). The second, left cover is shaped differently and is a separate item (https://www.microscopeparts.eu/part/99930).

There is no printing on the right cover - the interpupillary scale is printed on the left cover. When the interpupillary distance is changed, the right cover covers or uncovers part of the left cover and with it part of the scale placed there - and this is how the interpupillary distance value is read.

The cover is made of plastic and is screwed with four screws directly to the brass carrier plate, to which the eyepiece tube (https://www.microscopeparts.eu/part/99928) is also fastened.

This cover was removed from the Leitz Wetzlar binocular head P/N 512821/20 (also written 512 821) - but exactly the same one is used in other models of binocular and trinocular heads as well.

The same front panel design is found in, among others, the Leitz 512 923/20 and Leitz 512 815 trinocular heads - this cover will most likely fit those too.

Before you decide to use this cover in a Leitz Wetzlar head other than model 512 821/20, first compare the exact dimensions (the photos show a millimetre scale), and if you have any doubts, ask in internet groups and forums.

This is a service part for a microscope head - not for a specific microscope model. Such a head can be mounted on many Leitz Wetzlar microscope models (and even on microscopes from other makers), so no list of microscopes this cover fits can be given - it fits the head, and the user mounts the head wherever he wants.

In the "compatibility" section I list a few example Leitz Wetzlar microscope models that turn up on the second-hand market complete with the head this cover comes from - but this is definitely not a complete list. They include:
- Leitz Wetzlar Dialux 20 / Dialux 22 EB
- Leitz Wetzlar Laborlux K / Laborlux S
- Leitz Wetzlar Diaplan

On the last photos in the gallery you can see the Leitz Wetzlar 512821/20 binocular head, and with arrows I try to show which part this is and where it sits in the head.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux 20 microscope repair parts
  • Leitz 512821/20 rechte Frontblende Binokularkopf
  • Leitz 512 821 binocular head front cover plate right
  • Leitz Dialux 20 Frontblende Kunststoff gerissen
  • Leitz Dialux 22 EB binocular head plastic cover cracked
  • Leitz Laborlux S Abdeckung Augenabstand-Skala rechts
  • Leitz Laborlux K binocular head front panel cover replacement
  • Leitz Diaplan Kunststoff-Frontblende Ersatzteil
  • Leitz 512 923/20 trinocular head front cover plate
  • Leitz 512 815 binocular head cover plate 4 Schrauben
  • Leitz Bino Frontblende fehlt - Mechanik offen
  • Leitz binocular head cover plate missing eye distance scale
  • Leitz Ortholux Binokularkopf Frontabdeckung Kunststoff
  • Leitz SM-LUX Bino Abdeckplatte vorne
  • Leitz Laborlux 12 binocular head cover plate repair DIY
  • Leitz Ortholux Binokularkopf aufarbeiten Frontblende
  • krycí plastový panel binokulární hlavice Leitz
  • tapa frontal de plástico cabezal binocular Leitz Dialux
  • cubierta derecha cabezal binocular Leitz Laborlux
  • coperchio frontale in plastica testata binoculare Leitz Dialux
  • copertura destra testata binoculare Leitz Laborlux
  • prawa pokrywa panelu przedniego głowicy Leitz - wymiana
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

10 €

Name of the category to which this microscope part is classified.

Service and spare parts

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux 20

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as a service part, if you have a head in which this plastic part is in very poor condition: scratched, cracked or chipped
2026-10-23 00:04:32

1336 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99930
Leitz Wetzlar 512821/20 microscope left front cover plate with interpupillary scale for binocular head

The name of this microscope part.

Leitz Wetzlar 512821/20 microscope left front cover plate with interpupillary scale for binocular head

Description of this part for the microscope.

Left plastic front cover plate with interpupillary scale for the Leitz Wetzlar 512821/20 microscope binocular head and similar heads.

This is the left one of two ...

covers that close the internal interpupillary distance adjustment mechanism from the front (https://www.microscopeparts.eu/part/99929). The second, right cover is shaped differently and is a separate item (https://www.microscopeparts.eu/part/99931).

The interpupillary scale is printed on the left cover - there is no printing on the right cover. When the interpupillary distance is changed, the right cover covers or uncovers part of the left cover and with it part of the scale placed there - and this is how the interpupillary distance value is read.

The cover is made of plastic and is screwed with four screws directly to the brass carrier plate, to which the eyepiece tube (https://www.microscopeparts.eu/part/99928) is also fastened.

This cover was removed from the Leitz Wetzlar binocular head P/N 512821/20 (also written 512 821) - but exactly the same one is used in other models of binocular and trinocular heads as well.

The same front panel design is found in, among others, the Leitz 512 923/20 and Leitz 512 815 trinocular heads - this cover will most likely fit those too.

Before you decide to use this cover in a Leitz Wetzlar head other than model 512 821/20, first compare the exact dimensions (the photos show a millimetre scale), and if you have any doubts, ask in internet groups and forums.

This is a service part for a microscope head - not for a specific microscope model. Such a head can be mounted on many Leitz Wetzlar microscope models (and even on microscopes from other makers), so no list of microscopes this cover fits can be given - it fits the head, and the user mounts the head wherever he wants.

In the "compatibility" section I list a few example Leitz Wetzlar microscope models that turn up on the second-hand market complete with the head this cover comes from - but this is definitely not a complete list. They include:
- Leitz Wetzlar Dialux 20 / Dialux 22 EB
- Leitz Wetzlar Laborlux K / Laborlux S
- Leitz Wetzlar Diaplan

On the last photos in the gallery you can see the Leitz Wetzlar 512821/20 binocular head, and with arrows I try to show which part this is and where it sits in the head.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Leitz Dialux 20 microscope repair parts
  • Leitz 512821/20 linke Frontblende mit Augenabstand-Skala
  • Leitz 512 821 binocular head left front cover plate with scale
  • Leitz Dialux 20 Augenabstand-Skala abgerieben
  • Leitz Dialux 22 EB binocular head scale cover cracked
  • Leitz Laborlux S Frontblende mit Skala links Ersatz
  • Leitz Laborlux K binocular head interpupillary scale plate
  • Leitz Diaplan Kunststoff-Frontblende mit Skala
  • Leitz 512 923/20 trinocular head front cover plate with scale
  • Leitz 512 815 binocular head Skalenblende 4 Schrauben
  • Leitz Bino Augenabstand nicht ablesbar - Skala fehlt
  • Leitz binocular head eye distance scale unreadable
  • Leitz Ortholux Binokularkopf Frontabdeckung mit Skala
  • Leitz SM-LUX Bino Abdeckplatte vorne links
  • Leitz Laborlux 12 binocular head scale cover repair DIY
  • Leitz Ortholux Binokularkopf aufarbeiten Skalenblende
  • krycí plastový panel se stupnicí binokulární hlavice Leitz
  • tapa frontal izquierda con escala cabezal binocular Leitz Dialux
  • escala de distancia interpupilar cabezal binocular Leitz Laborlux
  • coperchio frontale sinistro con scala testata binoculare Leitz Dialux
  • scala interpupillare testata binoculare Leitz Laborlux
  • lewa pokrywa panelu przedniego ze skalą głowicy Leitz - wymiana
  • Leitz buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

10 €

Name of the category to which this microscope part is classified.

Service and spare parts

Abbreviated and full name of the manufacturer of this microscope part.

Leitz

Leitz Wetzlar

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Dialux 20

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Leitz)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • as a service part, if you have a head in which this plastic part is in very poor condition: scratched, cracked or chipped
2026-10-23 00:12:18