SERMIK_ID number under which this microscope part is placed in the database.
00966
|
PZO SK8 microscope mechanical stage - knobs (handwheels) and worm shaft
|
|
Description of this part for the microscope.
This is a service part for the PZO SK8 mechanical microscope stage.
It consists of a set of knobs and a horizontal worm shaft with a handle and screws.
...
This part is often damaged in PZO SK8 microscope stages: because the knobs extend beyond the microscope's outline after installation, the worm shaft often bends during transport, making it difficult to straighten properly.
The PZO SK8 is a mechanical microscope stage with horizontal knobs, primarily used in PZO MB30 microscopes, ML series models, and PZO MST-130/131 stereo microscopes - but is also sometimes installed in Studar and Biolar models.
Names, descriptions, terms, and search contexts under which this part is searched.
- PZO SK8 mechanical stage microscope repair parts
- PZO SK-8 mechanical stage
- PZO MB-30 Mikroskoptisch SK8
- stolik mikroskopowy PZO SK8
- PZO SK8 Kreuztisch Triebknöpfe mit Schneckenwelle
- PZO SK8 mechanical stage knobs and worm shaft
- PZO Biolar Kreuztisch SK8 Knopf
- PZO Studar / ML5 stage handwheels
- PZO SK8 Tischtrieb Knopf dreht durch - Ersatz
- ovladač křížového stolku PZO SK8
- mandos de la platina mecánica PZO SK8
- platina mecánica microscopio PZO Biolar
- manopole tavolino traslatore PZO SK8
- tavolino traslatore microscopio PZO Biolar
- PZO buy spare parts
|
The number of pieces of this microscope part that we have to offer.
1
|
Price in EURO for 1 piece of this microscope part. Price is negotiable.
20 €
|
|
Abbreviated and full name of the manufacturer of this microscope part.
PZO
Polskie Zaklady Optyczne
|
Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?
Model name of the equipment in which this microscopic part previously operated.
SK8 mechanical stage
Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.
(PZO)
Here it is written whether this part was removed from a microscope or from a larger microscope part.
part
|
List of microscope models this part is compatible with.
|
A list of potential uses for this part and when it might be needed.
-
as a repair part. The main reason for the need for replacement is stated in the description
|
|
|
|
SERMIK_ID number under which this microscope part is placed in the database.
99212
|
PZO Biolar DIC microscope MND-6 binocular head eyepiece diopter adjustment ring & right eyepiece prism
|
|
Description of this part for the microscope.
Eyepiece tube for eyepieces with diameter 23.2 mm and right eyepiece prism for the PZO MND-6 microscope head.
This is a tube with an assembled diopter adjustment
...
ring that allows correction of the vision defect of one eye and proper adjustment of image sharpness. The right eyepiece prism is integrated together with the tube.
Basic parameters: - Type: tube with diopter correction ring - Supported eyepiece diameter: 23.2 mm - Included: right eyepiece prism - For head model: PZO MND-6, both for models with black and with white housing.
This repair part (service element / replacement part) comes from a binocular head PZO MND-6 which was originally mounted on the microscopes: - PZO Biolar DIC - PZO Biolar B
However, because the PZO MND-6 head has a standard mounting interface typical for PZO microscopes (that is a dovetail mount with a diameter of 43 mm), this head can also be found mounted on other PZO microscopes such as: - Studar - MB-30
Additional information: the fluorescence microscope PZO Biolar FL was originally sold with a mono head (monocular head) - however the PZO MND6 head also fits this microscope model.
Hinweis - this tube with prism DOES NOT FIT heads that were originally sold with PZO Studar microscopes, even though these heads look very similar. Of course if a head from the Biolar model was mounted on a Studar microscope (because it fits), then this tube will be compatible, because it is a repair element for the HEAD and not for a specific microscope model.
Names, descriptions, terms, and search contexts under which this part is searched.
- PZO MND-6 microscope repair parts
- PZO Biolar microscope eyepiece tubus with diopter adjustment ring
- PZO Biolar DIK Okulartubus mit Dioptrieneinstellring
- PZO Biolar DIC - tubus okularowy z pierścieniem korekcji dioptrii
- PZO Biolar MND-6 Binokular Wartung
- PZO Bino Schmierstoffwechsel
- PZO MND-6 Okularprisma
- PZO Biolar microscope prism fungus
- PZO Biolar DIC Mikroskop Okularprisma Pilz Reinigung
- PZO MND-6 Binokularkopf Dioptrienring und Prisma rechts
- PZO Biolar DIC MND-6 binocular head diopter ring and right eyepiece prism
- dioptrický kroužek a pravý hranol binokulární hlavice PZO MND-6
- anillo de dioptrías y prisma derecho del cabezal binocular PZO MND-6
- repuesto cabezal para microscopio PZO Biolar
- anello diottrico e prisma destro della testata binoculare PZO MND-6
- ricambio testata per microscopio PZO Biolar
- pierścień dioptrii i prawy pryzmat głowicy PZO MND-6 Biolar
- PZO buy spare parts
|
The number of pieces of this microscope part that we have to offer.
1
|
Price in EURO for 1 piece of this microscope part. Price is negotiable.
45 €
|
|
Abbreviated and full name of the manufacturer of this microscope part.
PZO
Polskie Zaklady Optyczne
|
Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?
Model name of the equipment in which this microscopic part previously operated.
MND-6
Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.
(PZO)
Here it is written whether this part was removed from a microscope or from a larger microscope part.
part
|
List of microscope models this part is compatible with.
|
A list of potential uses for this part and when it might be needed.
-
as a service part in the form of a complete replacement module
-
very often this tube is dented and an eyepiece cannot be inserted
-
very often the diopter adjustment ring becomes damaged and does not work
-
...
-
if this element in the head you own is of very poor quality
-
if the eyepiece prism has been damaged (for example chipped, fungus has damaged the anti-reflection surface, the mirror surface has oxidized or has detached)
|
|
|
|
SERMIK_ID number under which this microscope part is placed in the database.
99215
|
PZO Biolar DIC microscope MND-6 binocular head central beamsplitter prism
|
|
Description of this part for the microscope.
This is the central prism of the PZO Biolar microscope binocular head (model PZO MND-6), responsible for splitting the light beam into the left and right optical paths.
...
This repair part (service element / replacement part) comes from a binocular head PZO MND-6 which was originally mounted on the microscopes: - PZO Biolar DIC - PZO Biolar B
However, because the PZO MND-6 head has a standard mounting interface typical for PZO microscopes (that is a dovetail mount with a diameter of 43 mm), this head can also be found mounted on other PZO microscopes such as: - Studar - MB-30
Additional information: the fluorescence microscope PZO Biolar FL was originally sold with a mono head (monocular head) - however the PZO MND6 head also fits this microscope model.
Names, descriptions, terms, and search contexts under which this part is searched.
- PZO MND-6 microscope repair parts
- PZO Biolar MND-6 Binokular Wartung
- PZO Bino Schmierstoffwechsel
- PZO MND-6 Prisma
- PZO Biolar microscope beamsplitter prism fungus
- PZO Biolar DIC Mikroskop Prisma Pilz Reinigung
- PZO MND-6 Binokularkopf Strahlteilerprisma zentral
- PZO Biolar DIC MND-6 binocular head central beamsplitter prism
- centrální děliče hranol binokulární hlavice PZO MND-6
- prisma divisor central del cabezal binocular PZO MND-6
- repuesto cabezal para microscopio PZO Biolar
- prisma divisore centrale della testata binoculare PZO MND-6
- ricambio testata per microscopio PZO Biolar
- centralny pryzmat dzielący głowicy PZO MND-6 Biolar
- PZO buy spare parts
|
The number of pieces of this microscope part that we have to offer.
1
|
Price in EURO for 1 piece of this microscope part. Price is negotiable.
45 €
|
|
Abbreviated and full name of the manufacturer of this microscope part.
PZO
Polskie Zaklady Optyczne
|
Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?
Model name of the equipment in which this microscopic part previously operated.
MND-6
Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.
(PZO)
Here it is written whether this part was removed from a microscope or from a larger microscope part.
part
|
List of microscope models this part is compatible with.
|
A list of potential uses for this part and when it might be needed.
-
as a service part in the form of a complete replacement module
-
if the prism has been damaged (for example chipped, fungus has damaged the anti-reflection surface, the mirror surface has oxidized or has detached)
|
|
|
|
SERMIK_ID number under which this microscope part is placed in the database.
99213
|
PZO Biolar DIC microscope MND-6 binocular head eyepiece tubus & left eyepiece prism
|
|
Description of this part for the microscope.
Eyepiece tube for eyepieces with diameter 23.2 mm and left eyepiece prism for the PZO MND-6 microscope head.
Basic parameters: - Type: eyepiece tube -
...
Supported eyepiece diameter: 23.2 mm - Included: left eyepiece prism - For head model: PZO MND-6, both for models with black and with white housing.
This repair part (service element / replacement part) comes from a binocular head PZO MND-6 which was originally mounted on the microscopes: - PZO Biolar DIC - PZO Biolar B
However, because the PZO MND-6 head has a standard mounting interface typical for PZO microscopes (that is a dovetail mount with a diameter of 43 mm), this head can also be found mounted on other PZO microscopes such as: - Studar - MB-30
Additional information: the fluorescence microscope PZO Biolar FL was originally sold with a mono head (monocular head) - however the PZO MND6 head also fits this microscope model.
Hinweis - this tube with prism DOES NOT FIT heads that were originally sold with PZO Studar microscopes, even though these heads look very similar. Of course if a head from the Biolar model was mounted on a Studar microscope (because it fits), then this tube will be compatible, because it is a repair element for the HEAD and not for a specific microscope model.
Names, descriptions, terms, and search contexts under which this part is searched.
- PZO MND-6 microscope repair parts
- PZO Biolar microscope eyepiece tubus
- PZO Biolar DIK Okulartubus
- PZO Biolar DIC - tubus okularowy
- PZO Biolar MND-6 Binokular Wartung
- PZO Bino Schmierstoffwechsel
- PZO MND-6 Okularprisma
- PZO Biolar microscope prism fungus
- PZO Biolar DIC Mikroskop Okularprisma Pilz Reinigung
- PZO MND-6 Binokularkopf Okulartubus und Prisma links
- PZO Biolar DIC MND-6 binocular head eyepiece tube and left prism
- tubus okuláru a levý hranol binokulární hlavice PZO MND-6
- tubo portaocular y prisma izquierdo del cabezal binocular PZO MND-6
- repuesto cabezal para microscopio PZO Biolar
- tubo portaoculare e prisma sinistro della testata binoculare PZO MND-6
- ricambio testata per microscopio PZO Biolar
- tubus okularowy i lewy pryzmat głowicy PZO MND-6 Biolar
- PZO buy spare parts
|
The number of pieces of this microscope part that we have to offer.
1
|
Price in EURO for 1 piece of this microscope part. Price is negotiable.
35 €
|
|
Abbreviated and full name of the manufacturer of this microscope part.
PZO
Polskie Zaklady Optyczne
|
Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?
Model name of the equipment in which this microscopic part previously operated.
MND-6
Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.
(PZO)
Here it is written whether this part was removed from a microscope or from a larger microscope part.
part
|
List of microscope models this part is compatible with.
|
A list of potential uses for this part and when it might be needed.
-
as a service part in the form of a complete replacement module
-
very often this tube is dented and an eyepiece cannot be inserted
-
if this element in the head you own is of very poor quality
-
...
-
if the eyepiece prism has been damaged (for example chipped, fungus has damaged the anti-reflection surface, the mirror surface has oxidized or has detached)
|
|
|
|
SERMIK_ID number under which this microscope part is placed in the database.
99211
|
PZO Biolar DIC microscope MND-6 binocular head cover case
|
|
Description of this part for the microscope.
PZO MND-6 microscope head case.
This repair part (service element / replacement part) comes from a binocular head PZO MND-6 which was originally mounted on the
...
microscopes: - PZO Biolar DIC - PZO Biolar B
However, because the PZO MND-6 head has a standard mounting interface typical for PZO microscopes (that is a dovetail mount with a diameter of 43 mm), this head can also be found mounted on other PZO microscopes such as: - Studar - MB-30
This part may be the answer to the following problems: - scratched PZO head housing - how to paint a PZO head? - how to replace a PZO head cover? - dropped Biolar head - dented Biolar PZO head housing
Names, descriptions, terms, and search contexts under which this part is searched.
- PZO MND-6 microscope repair parts
- PZO Biolar DIK Mikroskopkopf
- PZO Biolar DIC - budowa głowicy dwuokularowej
- PZO Biolar MND-6 Binokular Wartung
- PZO Bino Schmierstoffwechsel
- PZO Biolar DIC Mikroskop Binokular Reinigung
- PZO Biolar - das Gehäuse lackieren
- PZO MND-6 Binokularkopf Gehäusedeckel
- PZO Biolar DIC MND-6 binocular head cover case
- kryt binokulární hlavice PZO MND-6
- carcasa del cabezal binocular PZO MND-6
- repuesto cabezal para microscopio PZO Biolar
- coperchio della testata binoculare PZO MND-6
- ricambio testata per microscopio PZO Biolar
- obudowa głowicy PZO MND-6 Biolar
- PZO buy spare parts
|
The number of pieces of this microscope part that we have to offer.
1
|
Price in EURO for 1 piece of this microscope part. Price is negotiable.
25 €
|
|
Abbreviated and full name of the manufacturer of this microscope part.
PZO
Polskie Zaklady Optyczne
|
Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?
Model name of the equipment in which this microscopic part previously operated.
MND-6
Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.
(PZO)
Here it is written whether this part was removed from a microscope or from a larger microscope part.
part
|
List of microscope models this part is compatible with.
|
A list of potential uses for this part and when it might be needed.
-
as a service part in the form of a complete replacement module
-
if this element in the head you own is of very poor quality
|
|
|
|
SERMIK_ID number under which this microscope part is placed in the database.
99969
|
PZO Biolar - longitudinal guides and bearing balls for PZO SK14 microscope mechanical XY stage
|
|
Description of this part for the microscope.
Longitudinal guides and bearing balls, that is a repair part for the PZO SK14 microscope stage used in PZO Biolar microscopes and similar models.
Basic data of
...
these guides: Number of guides in the set: 2 Material: the guides are made of aluminium Number of bearing balls: 13 per guide Length of the guide: 114 mm Width of the guide: 6 mm Removed from: the mechanical stage PZO SK14 Which microscope this stage worked with: the PZO Biolar microscope
Important: these are longitudinal guides. They are responsible for moving the stage surface back and forth. They are not transverse guides for moving the specimen holder sideways - because the PZO SK14 stage, unlike many other stages, has NO transverse guides.
Please note: SK14 is a stage model made by the PZO company (SK = Stolik Krzyżowy, that is mechanical stage). The marking of this model (the marking "SK14") is on the stage. This stage was most often mounted on PZO Biolar microscopes, which carry no model name. As a result "SK14" is the only marking found on the microscope, and many people use the name "PZO SK14" - wrongly - for the whole microscope. This is a mistake: PZO SK14 is a stage model, not a microscope model.
The SK14 microscope stage these guides come from was mounted in a PZO Biolar B microscope. However, the same stage model was also used in other models of the Biolar microscope and in other microscopes made by this manufacturer, for example: - PZO Biolar DIC - PZO Biolar B2 - PZO Biolar GF - PZO MB 30 - PZO Studar
This item is not a spare part for repairing a microscope. It is a component of the microscope stage - and the stage can be used with any compatible PZO microscope.
Detailed photos of these guides are available in the gallery. Every photo shows a scale with a millimetre division. The last photo shows the whole PZO SK14 microscope stage, with an arrow pointing at the component in question and at where it sits in the stage, so that this part can be identified without any doubt.
Names, descriptions, terms, and search contexts under which this part is searched.
- PZO Biolar microscope repair parts
- PZO SK14 Mikroskoptisch klemmt und ruckelt
- PZO Biolar Kreuztisch neufetten und reinigen
- PZO SK14 Mikroskoptisch Längsführung ausgeschlagen
- Lagerkugeln aus dem PZO Mikroskoptisch verloren
- PZO Biolar Objekttisch zerlegen und schmieren
- Führungen aus Aluminium Mikroskoptisch PZO
- PZO Biolar Mikroskoptisch aufarbeiten
- PZO SK14 microscope stage stuck will not move
- PZO SK14 mechanical stage repair parts
- bearing balls lost PZO stage repair
- microscope stage regrease old grease hard
- PZO Biolar stage jerky movement repair
- restoring a PZO Biolar microscope stage
- stolik mikroskopowy PZO SK14 zablokował się
- prowadnice stolika PZO Biolar wymiana kulek
- stolik PZO SK14 trzeba przesmarować
- stolik mikroskopowy PZO Biolar nie przesuwa się
- zgubione kulki łożyskowe stolika PZO
- prowadnice wzdłużne stolika PZO SK14
- PZO SK14 to stolik a nie model mikroskopu
- podélné vedení s kuličkami stolku PZO Biolar
- guías longitudinales y bolas de la platina PZO Biolar
- repuesto platina microscopio PZO SK14
- platina microscopio PZO Biolar reparacion
- guide longitudinali e sfere del tavolino PZO Biolar
- ricambio tavolino microscopio PZO SK14
- tavolino microscopio PZO Biolar riparazione
- PZO buy spare parts
|
The number of pieces of this microscope part that we have to offer.
1
|
Price in EURO for 1 piece of this microscope part. Price is negotiable.
29 €
|
|
Abbreviated and full name of the manufacturer of this microscope part.
PZO
Polskie Zaklady Optyczne
|
Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?
Model name of the equipment in which this microscopic part previously operated.
Biolar
Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.
(PZO)
Here it is written whether this part was removed from a microscope or from a larger microscope part.
microscope
|
List of microscope models this part is compatible with.
|
A list of potential uses for this part and when it might be needed.
-
as a repair part, when you want to replace the whole damaged component
-
if you have a microscope stage in which this component still works, but is in very poor condition
-
...
-
if the bearing balls went missing during cleaning or repair
|
|
|
|
SERMIK_ID number under which this microscope part is placed in the database.
99968
|
PZO Biolar - long rack for transverse movement of PZO SK14 microscope stage
|
|
Description of this part for the microscope.
Rack for the transverse movement, that is a repair part for the PZO SK14 microscope stage used in PZO Biolar microscopes and similar models.
This is the rack -
...
the longer of the two in the stage - that works together with the larger pinion of the stage manipulator and is responsible for moving the specimen sideways.
Basic data of this rack: Length of the rack: 91 mm Number of teeth: 62 Material: brass How it is fixed: with 2 screws, which are included Removed from: the mechanical stage PZO SK14 Which microscope this stage worked with: the PZO Biolar microscope
Important: there are two racks of different length in the PZO SK14 microscope stage. The one I am offering here is the longer one, responsible for the transverse movement, that is for moving the specimen sideways. This is not the shorter rack responsible for moving the stage surface back and forth.
Please note: SK14 is a stage model made by the PZO company (SK = Stolik Krzyżowy, that is mechanical stage). The marking of this model (the marking "SK14") is on the stage. This stage was most often mounted on PZO Biolar microscopes, which carry no model name. As a result "SK14" is the only marking found on the microscope, and many people use the name "PZO SK14" - wrongly - for the whole microscope. This is a mistake: PZO SK14 is a stage model, not a microscope model.
The SK14 microscope stage this rack comes from was mounted in a PZO Biolar B microscope. However, the same stage model was also used in other models of the Biolar microscope and in other microscopes made by this manufacturer, for example: - PZO Biolar DIC - PZO Biolar B2 - PZO Biolar GF - PZO MB 30 - PZO Studar
A practical note on fitting: this mechanism needs a very tacky grease. If you need some, I will add it to the parcel - just write to me.
This item is not a spare part for repairing a microscope. It is a component of the microscope stage - and the stage can be used with any compatible PZO microscope.
Detailed photos of this rack are available in the gallery. Every photo shows a scale with a millimetre division. The last photo shows the whole PZO SK14 microscope stage, with an arrow pointing at the component in question and at where it sits in the stage, so that this part can be identified without any doubt.
Names, descriptions, terms, and search contexts under which this part is searched.
- PZO Biolar microscope repair parts
- PZO SK14 Kreuztisch bewegt sich nicht seitlich
- PZO Biolar Zahnstange aus Messing abgenutzt
- PZO SK14 Mikroskoptisch Zahnstange Ersatzteil
- Zahnstange beim Zerlegen verloren PZO Mikroskoptisch
- PZO Biolar Mikroskoptisch zerlegen und neufetten
- lange Zahnstange Querbewegung PZO Kreuztisch
- PZO Biolar Mikroskoptisch aufarbeiten
- PZO SK14 microscope stage will not move sideways
- long rack transverse movement PZO stage
- worn brass rack PZO microscope stage
- microscope stage regrease rack and pinion
- PZO Biolar stage repair parts
- restoring a PZO Biolar microscope stage
- zębatka stolika mikroskopowego PZO SK14 wyłamane ząbki
- listwa zębata stolika PZO Biolar wymiana
- stolik PZO SK14 nie przesuwa preparatu na boki
- mosiężna zębatka stolika PZO SK14
- stolik mikroskopowy PZO Biolar trzeba przesmarować
- zgubiona listwa zębata stolika PZO
- PZO SK14 to stolik a nie model mikroskopu
- ozubená tyč stolku mikroskopu PZO Biolar
- cremallera de laton de la platina PZO Biolar
- repuesto cremallera platina microscopio PZO SK14
- platina microscopio PZO Biolar reparacion
- cremagliera in ottone del tavolino PZO Biolar
- ricambio cremagliera tavolino microscopio PZO SK14
- tavolino microscopio PZO Biolar riparazione
- PZO buy spare parts
|
The number of pieces of this microscope part that we have to offer.
1
|
Price in EURO for 1 piece of this microscope part. Price is negotiable.
29 €
|
|
Abbreviated and full name of the manufacturer of this microscope part.
PZO
Polskie Zaklady Optyczne
|
Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?
Model name of the equipment in which this microscopic part previously operated.
Biolar
Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.
(PZO)
Here it is written whether this part was removed from a microscope or from a larger microscope part.
microscope
|
List of microscope models this part is compatible with.
|
A list of potential uses for this part and when it might be needed.
-
as a repair part, when you want to replace the whole damaged component
-
if you have a microscope stage in which this component still works, but is in very poor condition
-
...
-
if this rack went missing during cleaning or repair of the stage, or if, for example, its teeth have broken off
|
|