<< [ Previous ]

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.


More about part: Zeiss Axiolab short vernier scale for longitudinal movement of 453510 microscope stage | movable 10mm ruler (ID: 99974)


X.com Facebook Markdown Media-Markdown


Main Photo

Zeiss Axiolab short vernier scale for longitudinal movement of 453510 microscope stage | movable 10mm ruler
Zeiss Axiolab short vernier scale for longitudinal movement of 453510 microscope stage | movable 10mm ruler
Photo gallery

Description

Zeiss Axiolab short vernier scale for longitudinal movement of 453510 microscope stage | movable 10mm ruler

Side-mounted, movable vernier scale (a ruler with a 10 mm graduation) for the Zeiss 45 35 10 microscope stage, used in Carl Zeiss Axiolab microscopes.

A Zeiss 45 35 10 microscope stage (also written Zeiss 453510) has four rulers (vernier scales): two on top for the transverse movement and two on the side for the longitudinal movement. What I offer here is the short (10 mm) vernier scale, mounted on the side of the stage and used to read the position during the longitudinal movement (that is, when the whole stage surface moves back and forth).

Basic parameters of this vernier scale:

Material
the whole part is made of plastic, the scale with the graduation is merely stuck onto this part
Mounting
from below the stage, on two hex socket screws
Scale
10 mm (11 lines, the first one marked with a dot)
Movable
yes - this scale moves together with the lower, movable stage surface.


The fact that this vernier scale is screwed to the Zeiss 45 35 10 microscope stage from below with just two hex socket screws makes it fail fairly often.

Here are some problems that replacing this part will solve:

  • when the part carrying the side scale simply got lost during servicing of the stage and is missing
  • when this movable part with the graduation has snapped off under pressure from above. This happens often, because it is made of plastic and is held by only two point fixings
  • when years of rubbing have worn the stuck-on scale away so it is no longer readable, or it has come unstuck


The microscope stage this movable vernier scale came from was fitted to a Zeiss Axiolab re microscope, P/N 45 09 05 (also written 450905). The same stage model is, however, also fitted to these variants:

  • Zeiss Axiolab drb KT, which also carries the number 45 09 05 (450905)
  • Zeiss Axiolab E re, 45 09 07 (450907)
  • Zeiss Axiolab A, 45 09 09 (450909)
  • Zeiss Axiolab Pol, 45 09 10 (450910)


This element is not a repair part for the microscope. It is a part of the microscope stage - and the stage can be used with any compatible Zeiss microscope, and even with others whose holder will take such a stage, either seated or screwed on.

The gallery holds detailed photos of this screw-on vernier scale. Every photo includes a reference scale - a yellow ruler with a millimetre graduation placed next to the part. The last photo shows the whole Zeiss 453510 microscope stage, with an arrow marking which element is meant and where it sits on the stage, so that this part can be identified beyond doubt. The same photo also shows very clearly how this graduation is mounted.

Manufacturer

Zeiss - (Carl Zeiss West Germany) ➔ All parts

It comes from

This part was removed from the following microscope:

Zeiss Axiolab ➔ All parts

Why do you need this?

This microscope part is typically used for the following purposes:

  • as a repair part, by replacing the whole damaged element
  • if you have a microscope stage where this element still works but is in very poor condition
  • if this scale got lost while cleaning or repairing the stage
  • examples of damage are given in the description

Compatibility

This microscope part is compatible with the following microscope models, among others:

Names, descriptions, terms, and search contexts under which this part is searched.

Frequently Asked Questions (FAQ)

Below you will find answers to the most frequently asked questions (FAQ).

What can be found on this page?

This page contains a detailed description of the microscope component Zeiss - Axiolab short vernier scale for longitudinal movement of 453510 microscope stage | movable 10mm ruler

Is the microscope component offered here an original part?

YES - this is an original component. It is not a 3D-printed part nor a third-party replacement.

Who is the manufacturer of this component?

The manufacturer of this component is Zeiss (Carl Zeiss West Germany)

Is this microscope component new?

NO - this item was removed from Zeiss Axiolab microscope, has been inspected, cleaned, and is fully functional and ready for further use.

Which microscopes is this component compatible with?

This component is compatible with, among others, the following microscopes:
  • Zeiss 45 35 10 XY microscope stage
  • Zeiss Axiolab

Can I purchase this microscope component and how does the process work?

If you are interested in this component, contact the owner by clicking the "Show contact info" button on the page. No need to worry - clicking it does not create any transaction; it only displays the owner's contact details.

Who is this component intended for and for what purpose can it be used?

This component is most commonly used for the following purposes:
  • as a repair part, by replacing the whole damaged element
  • if you have a microscope stage where this element still works but is in very poor condition
  • if this scale got lost while cleaning or repairing the stage
  • examples of damage are given in the description

Are other microscope components from this manufacturer available?

YES. By clicking here you can view a list of all microscope components from this manufacturer available in the database.

Where can I view a photo gallery of this component from different angles?

A gallery with all photos of this component can be found on page , showing the component from multiple angles.
Contact details
If you need Zeiss Axiolab short vernier scale for longitudinal movement of 453510 microscope stage | movable 10mm ruler (ID 99974) , just write at info@microscopeparts.eu
Információk a Magyarországra történő szállításról

A magyar testvérek nem fizetnek szállításért.

Miért? Nos, ez egyszerű:

Lengyel-magyar két jó barát
Együtt harcol s issza borát
Vitéz s bátor mindkettője
Áldás szálljon mindkettőre
Price information
Sometimes, it may happen that I've completely missed the mark with the price and it's way too high. If you think so and would like to purchase the item, simply send me an email