Home page of the microscope service parts, repair and spare parts online catalog - Sermik-Oplatek Mikroskopservice Dresden f.n.n.Z

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.

Advanced search






The table below is the search result: "Zeiss Photomicroscope"

of 108 [Newest first]

Main table with a list of microscope parts

Photos PartIndex Short name Part name Description Number of pieces Price Category Manufacturer It comes from Compatible with Why do you need this? Added ↑

1259 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99840
Zeiss Ph2 F40/0,65 phase contrast microscope objective 460706 | 40x semi planachromat

The name of this microscope part.

Zeiss Ph2 F40/0,65 phase contrast microscope objective 460706 | 40x semi planachromat

Description of this part for the microscope.

Carl Zeiss (West Germany) microscope objective with 40x magnification, for Ph2 phase contrast.

Basic parameters:
Manufacturer: Carl Zeiss West ...

Germany
Designation: Ph2 F40/0,65 160/0,17
Manufacturer catalogue number: 46 07 06
Magnification: 40x
Correction: Semi-planachromatic
Numerical aperture N.A.: 0.65
Tube length: 160 mm
Parfocal length: 45 mm
Cover glass: yes, 0.17 mm thick
Immersion: no (a so-called dry objective)
Thread: RMS
Phase contrast: yes, the objective has an internal phase ring matching the Ph2 position in the condenser
Specimen protection: yes, the objective has a spring-loaded mechanism that protects the slide from being crushed

The letter "F" at the beginning of the objective model name (F 40 / 0.65) means that this is a semi-planachromatic objective, i.e. flatter than an achromat but less flat than a planachromat. "F" does not mean that the objective is intended for work with fluorescence light.

This objective fits practically any microscope from any manufacturer, provided it has an RMS thread and accepts 160 mm tube length objectives with a parfocal length of 33, 37 or 45 mm. A few example microscopes are listed in the "compatibility" section, but that list is not complete.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss KM microscope repair parts
  • Carl Zeiss KM / Standard 40x Phasenkontrast Mikroskopobjektiv
  • Carl Zeiss Universal 40x phase contrast microscope objective
  • Carl Zeiss Phasenkontrast-Mikroskop
  • Zeiss Photomicroscope Phasenkontrast
  • Carl Zeiss KF2 40x Phasenkontrast Kondensor
  • Zeiss Standard GFL Mikroskop Objektiv
  • Zeiss Phomi Phasenkontrast
  • Zeiss Ph2 F40/0.65 160/0.17 Objektiv 46 07 06
  • Zeiss 460706 phase contrast objective 40x
  • Zeiss Standard 14 Ph2 40x Phasenkontrast Objektiv Ersatz
  • Zeiss Axiostar / Axiolab Ph2 40x objective 160 mm
  • Zeiss Ph2 40x Frontlinse zerkratzt - Ersatz
  • Zeiss Ph2 40x objective fungus - replacement
  • Zeiss Axiovert 25 Ph2 40x Objektiv
  • objektiv fázový kontrast Ph2 40x Zeiss
  • objetivo de contraste de fases Ph2 40x Zeiss
  • objetivo Ph2 40x para microscopio Zeiss Standard
  • obiettivo a contrasto di fase Ph2 40x Zeiss
  • obiettivo Ph2 40x per microscopio Zeiss Standard
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

49 €

Name of the category to which this microscope part is classified.

Objective

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

KM

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • If you have a microscope without objectives and need to restock it using original parts
  • If you have a microscope that doesn't have an objective lens with this magnification and want to restock it
  • If you have such an objective lens, but it's of very poor quality or damaged
  • If you're cautious and want to have a spare objective lens
2026-10-03 21:05:45

1266 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99841
Zeiss Photomicroscope / PM-III metal nameplate with "Carl Zeiss Made in West Germany" logo from photo intermediate tube

The name of this microscope part.

Zeiss Photomicroscope / PM-III metal nameplate with "Carl Zeiss Made in West Germany" logo from photo intermediate tube

Description of this part for the microscope.

Manufacturer logo plate to be mounted on the photo intermediate tube of Carl Zeiss Photomicroscope microscopes.

It is a brass casting with a large Carl Zeiss logo ...

and a single line below it reading: Made in West Germany.

This is not the plate for the base of Zeiss Photomicroscope microscopes. Although it looks similar - it is not the plate for the body of the Zeiss Stereomicroscope either.

This plate has two pins on its inner side. The photo intermediate tube should have two holes into which these pins are pressed. For a firmer hold you can apply some glue to the underside of the plate.

In one of the last photos in the gallery you will see two photo-trino intermediate tubes lying side by side. As you can see, this plate is not fitted at the factory on every variant of the intermediate tube.
- I have not come across it (and I have seen no mounting holes) on the black intermediate tubes of the earliest Carl Zeiss Universal, Ultraphot and Photomicroscope models
- on the latest variants of the Photomicroscope III the logo is printed on the base (instead of a plate) and there is no plate on the intermediate tube

Importantly - intermediate tubes can be swapped between models of this class, so the surest way to tell whether this plate fits a particular tube is to check whether it has mounting holes.

Over the years this plate often fell off or was torn off, so on the second-hand market you can find microscopes with this element missing.

Some users like this style of the older models and, after cutting off the two mounting pins, they glue the plate onto a photo intermediate tube that has no mounting holes.

The last photo in the gallery shows several models of this microscope class standing side by side. Arrows mark the ones that carry a logo plate like the one offered here.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss Photomicroscope microscope repair parts
  • Zeiss Photomicroscope Firmenschild fehlt
  • Zeiss microscope logo plate fell off
  • Zeiss Universal Fototubus Firmenschild nachrüsten
  • Carl Zeiss Made in West Germany nameplate replacement
  • Zeiss Mikroskop Messingschild abgefallen
  • DIY Zeiss Photomicroscope nameplate mounting
  • štítek s logem Carl Zeiss mikroskop Photomicroscope
  • placa con logo Carl Zeiss microscopio Photomicroscope
  • chapa metálica con logotipo Carl Zeiss para microscopio
  • targhetta logo Carl Zeiss microscopio Photomicroscope
  • targhetta metallica con logo Carl Zeiss per microscopio
  • tabliczka z logo Carl Zeiss do mikroskopu Photomicroscope
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

15 €

Name of the category to which this microscope part is classified.

Stickers (nameplates)

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Photomicroscope

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if you own a microscope from which such a manufacturer logo plate has fallen off and you want to complete it with original parts
  • if you want to carry out a DIY modification and mount this plate on a photo intermediate tube that never had one
  • if you want to place this plate somewhere else, because you are a fan of Zeiss equipment
2026-10-04 20:27:39

1281 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

91070
Zeiss 473016 microscope binocular head eyepiece tube with diopter adjustment ring | 473012-9901 compatible

The name of this microscope part.

Zeiss 473016 microscope binocular head eyepiece tube with diopter adjustment ring | 473012-9901 compatible

Description of this part for the microscope.

Eyepiece tube with a 23.2 mm eyepiece seat for a microscope binocular head by Carl Zeiss (Oberkochen, West Germany).

This is the tube with the diopter adjustment ...

ring fitted, which compensates for the refractive error of one eye and lets you focus the image correctly. The tube without diopter adjustment is here: https://www.microscopeparts.eu/part/91069.

Basic parameters:
- Type: tube with diopter adjustment ring
- Diameter of eyepieces accepted: 23.2 mm
- Color: black

This tube fits the binocular heads:
- Zeiss 473016 (also written: 47 30 16-9901)
- Zeiss 473012 (also written: 47 30 12-9901)
- Zeiss 473011 (also written: 47 30 11-9901)
- Zeiss 473013 (also written: 47 30 13-9901)
and probably others, as Zeiss often used the same components in several head models.

Before fitting this tube into your own head you should above all:
- check the shape of the tube foot. For example, there is also a polarizing variant of the head, Zeiss 47 30 12-9902, in which the eyepiece tube seat has a different shape (you can see it here: https://www.microscopeparts.eu/part/00536)
- check how many screws hold it to the head
- check all the dimensions (the photos show a millimeter scale)

This is a service part for a microscope binocular head - not for one particular microscope model. Such a head can be mounted on many Zeiss microscope models (and even on microscopes from other makers), so no list of microscopes this tube fits can be given - it fits the head, and the user mounts the head wherever they want.

In the last photo, an arrow shows where this element is located inside the head, allowing precise identification.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss ICM 405 microscope repair parts
  • Zeiss ICM 405 Okularstutzen mit Dioptrienring
  • Zeiss Photomicroscope binocular head eyepiece tube replacement
  • Zeiss Standard Mikroskop Binokularkopf Okularstutzen tauschen
  • Zeiss 473016 / 47 30 16-9901 Okulartubus Dioptrienkorrektur
  • Zeiss 47 30 12-9901 binocular head eyepiece tube 23.2 mm
  • Zeiss 473011 / 473013 Okularstutzen 23.2 mm Ersatz
  • Zeiss binocular head diopter ring stuck - replacement eyepiece tube
  • Zeiss Photomicroscope eyepiece tube missing 23.2 mm
  • Dioptrienring am Zeiss Binokulartubus dreht durch
  • Okularstutzen am Zeiss Standard verbogen
  • Zeiss ICM 405 microscope binocular head repair DIY
  • okulárový tubus 23.2 mm k binokulární hlavici Zeiss
  • tubo portaocular 23.2 mm cabezal binocular Zeiss Standard
  • ajuste de dioptrías cabezal binocular Zeiss Photomicroscope
  • tubo portaoculare 23.2 mm testata binoculare Zeiss Standard
  • regolazione diottrica testata binoculare Zeiss Photomicroscope
  • tubus okularowy 23.2 mm do głowicy Zeiss - wymiana
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

25 €

Name of the category to which this microscope part is classified.

Service and spare parts

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

ICM 405

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • very often this tube is dented and an eyepiece cannot be inserted
  • very often the diopter adjustment ring becomes damaged and does not function
  • if you want diopter adjustment on both eyepiece tubes and replace the simple tube with one equipped with an adjustment ring
  • if you need a tube with precise worm adjustment for your own DIY purposes
2026-10-09 19:22:05

1282 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

91069
Zeiss 473012-9901 microscope 23.2mm binocular head eyepiece tube | 473016-9901 compatible

The name of this microscope part.

Zeiss 473012-9901 microscope 23.2mm binocular head eyepiece tube | 473016-9901 compatible

Description of this part for the microscope.

Eyepiece tube with a 23.2 mm eyepiece seat for a Carl Zeiss microscope binocular head (Oberkochen, West Germany).

This is the tube without a diopter adjustment ...

ring. The tube with the adjustment is here: https://www.microscopeparts.eu/part/91070.

This tube fits the binocular heads:
- Zeiss 473016 (also written: 47 30 16-9901)
- Zeiss 473012 (also written: 47 30 12-9901)
- Zeiss 473011 (also written: 47 30 11-9901)
- Zeiss 473013 (also written: 47 30 13-9901)
and probably others, as Zeiss often used the same components in several head models, trinocular and photo heads included.

Before fitting this tube into your own head you should above all:
- check the shape of the tube foot. For example, there is also a polarizing variant of the head, Zeiss 47 30 12-9902, in which the eyepiece tube seat has a different shape (you can see it here: https://www.microscopeparts.eu/part/00536)
- check how many screws hold it to the head
- check all the dimensions (the photos show a millimeter scale)
- and of course check that the mounting diameter of your eyepieces is 23.2 mm

This is a service part for a microscope binocular head - not for one particular microscope model. Such a head can be mounted on many Zeiss microscope models (and even on microscopes from other makers), so no list of microscopes this tube fits can be given - it fits the head, and the user mounts the head wherever they want.

The last photo has an arrow showing where this part sits in the head, so you can identify it without any doubt.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss ICM 405 microscope repair parts
  • Zeiss ICM 405 Okularstutzen mit Dioptrienring
  • Zeiss Photomicroscope binocular head eyepiece tube replacement
  • Zeiss Standard Mikroskop Binokularkopf Okularstutzen tauschen
  • Zeiss 473016 / 47 30 16-9901 Okulartubus Dioptrienkorrektur
  • Zeiss 47 30 12-9901 binocular head eyepiece tube 23.2 mm
  • Zeiss 473011 / 473013 Okularstutzen 23.2 mm Ersatz
  • Zeiss binocular head diopter ring stuck - replacement eyepiece tube
  • Zeiss Photomicroscope eyepiece tube missing 23.2 mm
  • Dioptrienring am Zeiss Binokulartubus dreht durch
  • Okularstutzen am Zeiss Standard verbogen
  • Zeiss ICM 405 microscope binocular head repair DIY
  • okulárový tubus 23.2 mm k binokulární hlavici Zeiss
  • tubo portaocular 23.2 mm cabezal binocular Zeiss Standard
  • ajuste de dioptrías cabezal binocular Zeiss Photomicroscope
  • tubo portaoculare 23.2 mm testata binoculare Zeiss Standard
  • regolazione diottrica testata binoculare Zeiss Photomicroscope
  • tubus okularowy 23.2 mm do głowicy Zeiss - wymiana
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

20 €

Name of the category to which this microscope part is classified.

Service and spare parts

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

ICM 405

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • very often this tube is dented and an eyepiece cannot be inserted
2026-10-10 00:29:31

1288 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99870
Zeiss Photomicroscope III RS power supply cable with 12 pin plug, 2x6 flat contacts, from microscope base

The name of this microscope part.

Zeiss Photomicroscope III RS power supply cable with 12 pin plug, 2x6 flat contacts, from microscope base

Description of this part for the microscope.

Carl Zeiss Photomicroscope III RS power supply cable with 12 pin plug, 2x6 flat contacts, from microscope base

This is one of two cables coming out of the base of ...

the Zeiss Photomicroscope III microscope. The following cables come out of it:
- with a 12 pin plug (2x6)
- with a 22 pin plug (2x10 + 2)

The cable presented here ends with a 12 pin plug, that is 6 rows of two flat contacts each. Marking on the plug: "Siemens DIN41622 VG95322 A12".

The cable was tested before being removed from a working microscope. The plug is fully functional, its plastic housing is neither broken nor crumbled, and all contacts are straight. Attaching / soldering on the base side has to be taken care of on your own.

Several names are used for this microscope model, among others:
- Carl Zeiss Photomicroscope III
- Carl Zeiss Phomi III
- Carl Zeiss PM III
- Zeiss Photomicroscope III RS
- Zeiss Phomi 3
- Zeiss PM3 RS

Replacing this cable can solve, among others, the following problems:
- when the microscope has a cut off cable, which is common when it comes from an institution that scraps electrical equipment this way
- when the microscope has a cable with a plug whose housing is broken, cracked or chipped
- when the microscope has a cable ending in a plug with broken off flat contacts
- when the microscope has a cable in which the plug has a damaged latch

A new plug of this type can be bought today. It is the DIN 41622 standard, a two row arrangement of 3.0 x 1 mm blade contacts, 12 poles - produced continuously for decades and offered today by Telegärtner, Binder, MPE and EVG among others. At Telegärtner the 12 pole male connector carries the number 100023261, and the matching female connector the number 100023250. One has to keep in mind, however, that this is only the contact insert itself: the cable housing (metal or plastic) together with the mounting trough is bought separately, the guide pins that also serve as coding are bought separately, the cable of the right cross section is bought separately, and all twelve contacts have to be soldered. Some users will appreciate owning an original cable with a period plug whose coding matches their microscope, while others will be glad that I have given the designations of the new equivalents and can go their own way.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss Photomicroscope III RS microscope repair parts
  • Zeiss Photomicroscope III Kabel zum Netzgerät
  • Zeiss Phomi III power supply cable 12 pin
  • Zeiss PM III Anschlusskabel Stecker 12-polig
  • Zeiss Photomikroskop III Kabel aus dem Stativfuß
  • Zeiss Photomicroscope III RS Kabel abgeschnitten
  • Zeiss Phomi III Steckergehäuse gebrochen
  • Zeiss PM III broken plug flat contacts
  • Zeiss Photomicroscope III cut power cable
  • Zeiss PM III Kabel ersetzen reparieren
  • Zeiss Photomicroscope III power cable replacement DIY
  • Siemens DIN 41622 Stecker 12-polig Zeiss Mikroskop
  • Zeiss Photomicroscope VG 95322 Steckverbinder
  • Opton Photomicroscope III Netzgerät 47 20 83
  • kabel zasilający do mikroskopu Zeiss Photomicroscope III
  • napájecí kabel k mikroskopu Zeiss Photomicroscope III
  • cable de alimentación microscopio Zeiss Photomicroscope III
  • conector 12 pines microscopio Zeiss Phomi III
  • cavo di alimentazione microscopio Zeiss Photomicroscope III
  • connettore 12 poli microscopio Zeiss PM III
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

25 €

Name of the category to which this microscope part is classified.

Other

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Photomicroscope III RS

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if you own a microscope without this cable, or with a damaged cable or plug
  • a list of several cases in which replacing the cable may be necessary can be found in the description
2026-10-11 20:42:52

1289 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99871
Zeiss Photomicroscope III RS cable supplying exposure automation with 22 pin plug, 2x10 + 2 flat contacts, from microscope base

The name of this microscope part.

Zeiss Photomicroscope III RS cable supplying exposure automation with 22 pin plug, 2x10 + 2 flat contacts, from microscope base

Description of this part for the microscope.

Cable supplying the exposure automation, to the power supply, with 22 pin plug, 2x10 + 2 flat contacts, from the base of the Carl Zeiss Photomicroscope III ...

microscope

This is one of two cables coming out of the base of the Zeiss Photomicroscope III microscope. The following cables come out of it:
- with a 12 pin plug (2x6)
- with a 22 pin plug (2x10 + 2)

The cable presented here ends with a 22 pin plug, that is 10 rows of two flat contacts each plus two single contacts in the middle. In the Zeiss manual the matching socket on the power supply is described as a 22 pole socket for the supply voltages of the automatic exposure control. There is no standard designation on the plug - only the marking "Siemens" and the letter "R" are visible.

The cable was tested before being removed from a working microscope. The plug is fully functional, its plastic housing is neither broken nor crumbled, and all contacts are straight. Attaching / soldering on the base side has to be taken care of on your own.

Several names are used for this microscope model, among others:
- Carl Zeiss Photomicroscope III
- Carl Zeiss Phomi III
- Carl Zeiss PM III
- Zeiss Photomicroscope III RS
- Zeiss Phomi 3
- Zeiss PM3 RS

Replacing this cable can solve, among others, the following problems:
- when the microscope has a cut off cable, which is common when it comes from an institution that scraps electrical equipment this way
- when the microscope has a cable with a plug whose housing is broken, cracked or chipped
- when the microscope has a cable ending in a plug with broken off flat contacts
- when the microscope has a cable in which the plug has a damaged latch

I have not found a new 22 pole plug in the current catalogues of the makers of this blade connector family - this pole count falls outside the range produced today. What remains is the second hand market. An original, working cable with a period plug saves you that search.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss Photomicroscope III RS microscope repair parts
  • Zeiss Photomicroscope III Kabel Belichtungsautomatik
  • Zeiss Phomi III exposure automation cable 22 pin
  • Zeiss PM III Anschlusskabel Stecker 22-polig
  • Zeiss Photomikroskop III Kabel aus dem Stativfuß
  • Zeiss Photomicroscope III RS Kabel abgeschnitten
  • Zeiss Phomi III Steckergehäuse gebrochen
  • Zeiss PM III broken plug flat contacts
  • Zeiss Photomicroscope III cut cable exposure control
  • Zeiss PM III Kabel ersetzen reparieren
  • Zeiss Photomicroscope III cable replacement DIY
  • Siemens Messerleiste 22-polig Zeiss Mikroskop
  • Zeiss Photomicroscope III Belichtungsautomatik Versorgungsspannung
  • Opton Photomicroscope III Netzgerät 47 20 83
  • kabel automatyki naświetlania do mikroskopu Zeiss Photomicroscope III
  • napájecí kabel k mikroskopu Zeiss Photomicroscope III
  • cable microscopio Zeiss Photomicroscope III automatismo de exposición
  • conector 22 pines microscopio Zeiss Phomi III
  • cavo microscopio Zeiss Photomicroscope III esposizione automatica
  • connettore 22 poli microscopio Zeiss PM III
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

25 €

Name of the category to which this microscope part is classified.

Other

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

Photomicroscope III RS

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if you own a microscope without this cable, or with a damaged cable or plug
  • a list of several cases in which replacing the cable may be necessary can be found in the description
2026-10-11 21:14:42

1317 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99913
Zeiss top lens of CPL W 10x/18 464022-9901 microscope eyepiece

The name of this microscope part.

Zeiss top lens of CPL W 10x/18 464022-9901 microscope eyepiece

Description of this part for the microscope.

Top lens of the Zeiss CPL W 10x/18 microscope eyepiece

Most important: this is not a complete microscope eyepiece. This is a service part - a component for ...

repairing the eyepiece.

Lens position: this is the topmost lens of the microscope eyepiece, called the eye lens
Lens construction: this is a cemented lens, flat on one side and convex on the other
Matching eyepiece: this is the lens from the Zeiss West Germany CPL W 10x/18 eyepiece, model number 464022-9901

This lens is not a replacement part for the microscope. It is a part for repairing a microscope eyepiece - and that eyepiece can be used in various microscopes, even from manufacturers other than Carl Zeiss. A few microscopes this eyepiece can be used with are listed in the "compatibility" section, but this is definitely not a complete list. It is safe to assume that the Zeiss CPL W 10x/18 eyepiece can be used with any microscope from any manufacturer whose head has a 23.2 mm eyepiece tube diameter.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss KF 2 microscope repair parts
  • Zeiss CPL W 10x/18 Mikroskop-Okular obere Linse gesprungen
  • Zeiss CPL W 10x/18 464022-9901 microscope eyepiece top lens replacement
  • CPL W 10x/18 microscope eyepiece lens cracked
  • Zeiss Standard 14 Mikroskop-Okular obere Linse Ersatz
  • Zeiss Standard WL Mikroskop-Okularlinse zerkratzt
  • Zeiss KF2 microscope eyepiece top lens chipped
  • Zeiss Photomicroscope eyepiece 23.2mm repair part
  • verkittete Linse Zeiss Mikroskop-Okular reparieren
  • Zeiss West Germany Mikroskop-Okular CPL W 10x/18 Ersatzteil
  • repair Zeiss CPL W microscope eyepiece lens DIY
  • Zeiss Standard 14 Mikroskop-Okular zerlegen
  • Zeiss Standard WL Mikroskop-Okular optisch aufarbeiten
  • horní čočka okuláru mikroskopu Zeiss CPL W 10x/18
  • lente superior del ocular de microscopio Zeiss
  • repuesto lente ocular microscopio Zeiss Standard
  • lente superiore oculare microscopio Zeiss
  • ricambio lente oculare microscopio Zeiss CPL W 10x/18
  • górna soczewka okularu mikroskopowego Zeiss CPL W 10x/18
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

7 €

Name of the category to which this microscope part is classified.

Lenses

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

KF 2

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if the top lens of the Carl Zeiss CPL W 10x/18 eyepiece is damaged, for example scratched, cracked or chipped
  • if the cement between the two parts of this lens (because it is a cemented lens) has discoloured or the two lens elements have started to separate
2026-10-18 21:42:52

1318 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99920
Zeiss - housing for CPL W 10x/18 464022-9901 microscope eyepiece

The name of this microscope part.

Zeiss - housing for CPL W 10x/18 464022-9901 microscope eyepiece

Description of this part for the microscope.

Complete plastic housing of the Zeiss CPL W 10x/18 microscope eyepiece

Most important: this is not a complete microscope eyepiece. This is a service part - ...

the body only, without optics.

What is included: three parts - the lower sleeve that goes into the eyepiece tube of the head, the retaining ring that holds the lenses inside the housing, and the upper sleeve with the engraving
Material: all parts of the housing are made of plastic - this is unusual, because in eyepieces of this class the bodies are normally metal
Marking on the body: ZEISS West Germany CPL W 10x/18, number 464022-9901
Mounting diameter: 23.2mm - a standard eyepiece tube

This housing is not a replacement part for the microscope. It is a part for repairing a microscope eyepiece - and that eyepiece can be used in various microscopes, even from manufacturers other than Carl Zeiss. A few microscopes this eyepiece can be used with are listed in the "compatibility" section, but this is definitely not a complete list. It is safe to assume that the Zeiss CPL W 10x/18 eyepiece can be used with any microscope from any manufacturer whose head has a 23.2 mm eyepiece tube diameter.

The plastic this eyepiece housing is made of can be damaged in various ways. It often cracks, gets scratched, or deforms and partly melts from heat - the proximity of a bulb, a lamp or a soldering iron is enough, and very often the culprit is simply the cigarette held in the same hand that turns the focus knobs. In that case - especially when the optics inside are still intact - you can simply replace the housing with the one offered here.

Here you will find the top lens for this eyepiece: https://www.microscopeparts.eu/part/99913.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Zeiss KF 2 microscope repair parts
  • Zeiss CPL W 10x/18 Mikroskop-Okular Gehäuse gebrochen
  • Zeiss CPL W 10x/18 464022-9901 microscope eyepiece housing replacement
  • CPL W 10x/18 microscope eyepiece body cracked
  • Zeiss Standard 14 Mikroskop-Okular Gehäuse Ersatz
  • Zeiss Standard WL Mikroskop-Okular Kunststoffhülse zerkratzt
  • Zeiss KF2 microscope eyepiece barrel damaged
  • Zeiss Photomicroscope eyepiece 23.2mm repair part
  • Zeiss Mikroskop-Okular angeschmort Kunststoff
  • Zeiss West Germany Mikroskop-Okular CPL W 10x/18 Ersatzteil
  • build DIY projection eyepiece microscope housing
  • Zeiss Standard 14 Mikroskop-Okular zerlegen
  • Zeiss Standard WL Mikroskop-Okular Gehäuse austauschen
  • Zeiss 46 40 22-9901 Mikroskop-Okular
  • plastové pouzdro okuláru mikroskopu Zeiss CPL W 10x/18
  • carcasa del ocular de microscopio Zeiss
  • repuesto cuerpo ocular microscopio Zeiss Standard
  • corpo oculare microscopio Zeiss
  • ricambio custodia oculare microscopio Zeiss CPL W 10x/18
  • obudowa okularu mikroskopowego Zeiss CPL W 10x/18
  • Zeiss buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

7 €

Name of the category to which this microscope part is classified.

Eyepieces

Abbreviated and full name of the manufacturer of this microscope part.

Zeiss

Carl Zeiss West Germany

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

KF 2

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Zeiss)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if the body of the Carl Zeiss CPL W 10x/18 eyepiece is cracked, broken out or chipped, but the lenses are intact
  • if the housing has deformed from heat or is scorched, and the eyepiece no longer sits straight in the tube or has started to jam in it
  • if the plastic sleeve is scratched and scuffed, often with damaged markings
  • if you have various lenses and want to build your own DIY eyepiece, for example a projection photo eyepiece, and only need a complete housing
2026-10-18 23:17:25