Home page of the microscope service parts, repair and spare parts online catalog - Sermik-Oplatek Mikroskopservice Dresden f.n.n.Z

Webpage www.microscopeparts.eu - sale of original, used and refurbished service, repair, and replacement parts for student, biological, laboratory, measuring, toolmakers, and stereo microscopes. Mail order.

Advanced search







of 1201 [Newest first]

Main table with a list of microscope parts

Photos PartIndex Short name Part name Description Number of pieces Price Category Manufacturer It comes from Compatible with Why do you need this? Added ↑

1229 - Thumbnail photo showing this microscope part.

SERMIK_ID number under which this microscope part is placed in the database.

99823
Nikon TMS / Labophot-2 Microscope Ph3 40 DL 0.55 LWD 160/0-2 Objective | 40x Phase Contrast with Long Working Distance and Correction Collar

The name of this microscope part.

Nikon TMS / Labophot-2 Microscope Ph3 40 DL 0.55 LWD 160/0-2 Objective | 40x Phase Contrast with Long Working Distance and Correction Collar

Description of this part for the microscope.

Achromatic Nikon Ph3 DL 40x / 0.55 LWD microscope objective for brightfield and phase contrast, with 0 - 2.0 mm correction collar, for 160 mm tube length - ...

for inverted and upright biological microscopes, made in Japan.

Basic objective parameters:
Manufacturer: Nikon, Japan
Model: Ph3 40 DL 0.55 LWD 160/0-2
Magnification: 40x
Numerical aperture (N.A.): 0.55
Optical correction: achromat
Phase contrast: Ph3 DL - Ph3 indicates the size of the phase ring (requires a matching Ph3 annulus in the condenser), DL (Dark Low) means dark, i.e. positive phase contrast - the object appears darker than the background
Working distance (WD): ~2.1 - 2.5 mm - LWD (Long Working Distance)
Correction collar: compensates for cover glass or vessel bottom thickness in the range 0 - 2.0 mm
Cover glass: the objective can be used without a cover glass, with a standard cover glass approx. 0.17 mm thick, and also with specimens observed through the bottom of a Petri dish up to 2.0 mm thick
Immersion: no (dry objective)
Tube length: 160 mm
Parfocal length: 45 mm
Thread: RMS
Optics: CF (Nikon CF-160) - requires no compensating eyepiece and allows photography by direct projection

This objective is suitable for:
- inverted microscopes - observation through the bottom of a Petri dish or cell culture flask
- upright biological microscopes - observation of specimens with or without a cover glass

Phase contrast work requires a compatible phase contrast condenser or a slider with a phase contrast annulus.

Commonly used, inexpensive cover glasses are 0.17 mm thick mainly in theory. Even the standard for class #1.5 allows a range of 0.16 - 0.19 mm, and in cheap Chinese cover glasses you will find in practice pieces from approx. 0.13 to 0.25 mm, often not matching the thickness stated on the box. Only #1.5H (high precision) cover glasses have a guaranteed thickness of 0.170 mm with a tolerance of +/- 0.005 mm. Variation in cover glass thickness clearly degrades image contrast and resolution (spherical aberration). The correction collar fitted to the objective offered here lets you adjust the optics to the combined thickness of the cover glass and the medium layer beneath it. This compensates for most of the variation found in practice.

In addition, the correction collar of this objective can be set to "0" for work without a cover glass, or to large values (up to 2.0 mm) to adapt the optics to observation through a microscope slide (0.8 - 1.2 mm), a glass Petri dish (usually 1.5 - 2.0 mm - thicker dishes are outside the collar range) or a plastic Petri dish (usually approx. 1 mm, in the range 0.8 - 1.2 mm).

This objective fits practically any microscope from any manufacturer, provided it has an RMS thread and uses objectives for 160 mm tube length with a parfocal length of 33, 37 or 45 mm. Some example microscopes are listed in the "compatibility" section, but the list is not complete.

Names, descriptions, terms, and search contexts under which this part is searched.

  • Nikon TMS microscope repair parts
  • Nikon TMS inverted microscope Ph3 40x LWD objective cell culture
  • Nikon TMS inverses Mikroskop Phasenkontrast Objektiv 40x
  • Nikon CF Ph3 DL 40x 0.55 LWD 160/0-2 objective Petri dish
  • Nikon Ph3 DL 40x Objektiv Petrischale Korrekturring
  • Nikon Labophot-2 phase contrast 40x objective correction collar
  • Nikon Labophot-2 Phasenkontrast Objektiv 40x großer Arbeitsabstand
  • Nikon buy spare parts

The number of pieces of this microscope part that we have to offer.

1

Price in EURO for 1 piece of this microscope part. Price is negotiable.

100 €

Name of the category to which this microscope part is classified.

Objective

Abbreviated and full name of the manufacturer of this microscope part.

Nikon

Nikon Instruments (Nikon Corp.)

Where has this microscope part been operating so far? From what microscope or larger microscope assembly was it removed?

Model name of the equipment in which this microscopic part previously operated.

TMS

Abbreviated name of the manufacturer of the equipment in which this microscopic part previously operated.

(Nikon)

Here it is written whether this part was removed from a microscope or from a larger microscope part.

microscope

List of microscope models this part is compatible with.

A list of potential uses for this part and when it might be needed.

  • if your microscope is missing a 40x objective - for brightfield or phase contrast
  • if you observe cell cultures, algae, protozoa or fungi in Petri dishes on an inverted microscope
  • if a standard 40x objective cannot focus through the thick bottom of a Petri dish or culture flask, or touches the vessel
  • if you want to observe living, unstained specimens in phase contrast
  • if you need an objective with correction for cover glass or vessel bottom thickness
  • if you work with specimens without a cover glass
  • if you want to photograph specimens by direct projection
  • if you already have such an objective, but it is damaged or of very poor quality
2026-09-26 19:59:43